OEM Manufacturer Endotoxin Assay Kit - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo


Product Detail

Related Video

Feedback (2)

Our firm has been concentrating on brand strategy. Customers' satisfaction is our best advertising. We also offer OEM provider for Pipette tip box, Bacteria Endotoxin Test, Endotoxin Free Microplate, First company, we understand each other. Further more company, the trust is getting there. Our enterprise normally at your provider anytime.
OEM Manufacturer Endotoxin Assay Kit - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo Detail:

LAL Reagent Water ( Water for Bacterial Endotoxins Test / Water for BET / TAL Reagnt Water ) 

1. Product Information

LAL Reagent Water (Water for Bacterial Endotoxins Test or BET Water or Water for BET is specially processed super-purified endotoxin free water is used for Endotoxin test. Its endotoxin concentration is less than 0.005 EU/ml. Various packages, such as 2ml, 10ml, 50ml, 100ml and 500ml per unit, are provided for users’ convenience. LAL Reagent Water (Water for BET) could be used to dilute the assay sample, construct the stand curve, or reconstitute the Lyophilized Amebocyte Lysate reagents. 

2. Product Parameter

Endotoxin level: ≤0.005 EU/ml

Water for Bacterial Endotoxins Test is specially processed water is used for endotoxin detection. Its endotoxin concentration is less than 0.005EU/ml. We also provide water for BET with endotoxin level less than 0.001EU/ml for the assay sensitivity 0.001 to 5EU/ml kinetic chromogenic assay.

 

3. Product Features and Application

Endotoxin Free Water (Water for BET, LAL Reagent water, Endotoxin free water or BET water) is specially processed water intended for reconstitution of Lyophilized Amebocyte Lysate and Control Standard Endotoxin (CSE), and to dilute samples and control standards in the endotoxin assay operation.

For reconstitution of Lyophilized Amebocyte Lysate or Amebocyte Lysate, dilution of the test samples and Control Standard Endotoxin, preparation endotoxin free buffers, and construction of the standard curve. 500ml BET water main apply in extract endotoxins from medical devices. 

Catalog No.

Volume (ml/vial)

Package

TRW02

2ml in Ampoule

In Ampoule, 10 Ampoules/Pack

TRW05

5ml in Ampoule

 In Ampoule, 10 Ampoules/Pack

TRW10

10ml in Ampoule

 In Ampoule, 10 Ampoules/Pack

TRW50

50ml in Glass Vial

In Glass Vial, 10 Vials/Pack

TRW100

100ml in Glass Vial

 In Glass Vial, 10 Vials/Pack

TRW500

500ml in Glass Bottle

1 Vial

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

What is BET water (bacterial endotoxin test water)?

Bacterial endotoxin test water that is endotoxin free level water, it mainly use for endotoxin test assay in the operation of reconstitution and dilution.

Such as, reconstitute lyophilized lysate reagent, control standard endotoxin dilution reconstitution and dilution, and samples dilutions.

Bioendo BET water (Water for BET) can be named TAL reagent water or LAL reagent water. LAL (lyophilized amebocyte lysate).


Product detail pictures:

OEM Manufacturer Endotoxin Assay Kit - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo detail pictures

OEM Manufacturer Endotoxin Assay Kit - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo detail pictures

OEM Manufacturer Endotoxin Assay Kit - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo detail pictures


Related Product Guide:

continue to enhance, to be certain solution top quality in line with market and buyer standard requirements. Our corporation has a excellent assurance program are actually established for OEM Manufacturer Endotoxin Assay Kit - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo , The product will supply to all over the world, such as: South Africa, Bandung, Switzerland, We have top engineers in these industries and an efficient team in the research. What is more, we have our own archives mouths and markets in China at low cost. Therefore, we can meet different inquiries from different clients. Please find our website to check more information from our products.
  • The company can keep up with the changes in this industry market, product updates fast and the price is cheap, this is our second cooperation, it's good.
    5 Stars By Sabrina from Italy - 2017.08.18 18:38
    We are old friends, the company's product quality has been always very good and this time the price is also very cheap.
    5 Stars By Mag from Ghana - 2018.12.22 12:52

    Leave Your Messages

    Related products

    • Manufactur standard Endotossine LAL Test - Rapid Gel Clot single test kit – Bioendo

      Manufactur standard Endotossine LAL Test - Rap...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • Trending Products Bacterial Endotoxin Test For Water For Injection - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Trending Products Bacterial Endotoxin Test For ...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Best quality limulus lysate assay - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo

      Best quality limulus lysate assay - Endotoxin-...

      Endotoxin-specific Lyophilized Amebocyte Lysate 1. Product Information Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples ...

    • Cheap PriceList for Endotoxin free reservoir - Control Standard Endotoxin (CSE) – Bioendo

      Cheap PriceList for Endotoxin free reservoir -...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • 2022 wholesale price Chromogenic LAL test - Endpoint Chromogenic Kit EC80545 – Bioendo

      2022 wholesale price Chromogenic LAL test - En...

      Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) 1. Product Information Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum abso...

    • Factory made hot-sale Bacterial Endotoxin Test Validation - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Factory made hot-sale Bacterial Endotoxin Test ...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...