We are experienced manufacturer. Wining the majority from the crucial certifications of its market for Endotoxin Detection Methods, Pyrogen free tip, Bioendo Endotoxin, By 10 years effort, we attract customers by competitive price and excellent service. Moreover, it's our honest and sincerity, which help us always be clients' first choice.
OEM Manufacturer Endotoxin Assay Kit - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo Detail:

LAL Reagent Water ( Water for Bacterial Endotoxins Test / Water for BET / TAL Reagnt Water ) 

1. Product Information

LAL Reagent Water (Water for Bacterial Endotoxins Test or BET Water or Water for BET is specially processed super-purified endotoxin free water is used for Endotoxin test. Its endotoxin concentration is less than 0.005 EU/ml. Various packages, such as 2ml, 10ml, 50ml, 100ml and 500ml per unit, are provided for users’ convenience. LAL Reagent Water (Water for BET) could be used to dilute the assay sample, construct the stand curve, or reconstitute the Lyophilized Amebocyte Lysate reagents. 

2. Product Parameter

Endotoxin level: ≤0.005 EU/ml

Water for Bacterial Endotoxins Test is specially processed water is used for endotoxin detection. Its endotoxin concentration is less than 0.005EU/ml. We also provide water for BET with endotoxin level less than 0.001EU/ml for the assay sensitivity 0.001 to 5EU/ml kinetic chromogenic assay.

 

3. Product Features and Application

Endotoxin Free Water (Water for BET, LAL Reagent water, Endotoxin free water or BET water) is specially processed water intended for reconstitution of Lyophilized Amebocyte Lysate and Control Standard Endotoxin (CSE), and to dilute samples and control standards in the endotoxin assay operation.

For reconstitution of Lyophilized Amebocyte Lysate or Amebocyte Lysate, dilution of the test samples and Control Standard Endotoxin, preparation endotoxin free buffers, and construction of the standard curve. 500ml BET water main apply in extract endotoxins from medical devices. 

Catalog No.

Volume (ml/vial)

Package

TRW02

2ml in Ampoule

In Ampoule, 10 Ampoules/Pack

TRW05

5ml in Ampoule

 In Ampoule, 10 Ampoules/Pack

TRW10

10ml in Ampoule

 In Ampoule, 10 Ampoules/Pack

TRW50

50ml in Glass Vial

In Glass Vial, 10 Vials/Pack

TRW100

100ml in Glass Vial

 In Glass Vial, 10 Vials/Pack

TRW500

500ml in Glass Bottle

1 Vial

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

What is BET water (bacterial endotoxin test water)?

Bacterial endotoxin test water that is endotoxin free level water, it mainly use for endotoxin test assay in the operation of reconstitution and dilution.

Such as, reconstitute lyophilized lysate reagent, control standard endotoxin dilution reconstitution and dilution, and samples dilutions.

Bioendo BET water (Water for BET) can be named TAL reagent water or LAL reagent water. LAL (lyophilized amebocyte lysate).


Product detail pictures:

OEM Manufacturer Endotoxin Assay Kit - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo detail pictures

OEM Manufacturer Endotoxin Assay Kit - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo detail pictures

OEM Manufacturer Endotoxin Assay Kit - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo detail pictures


Related Product Guide:

"Sincerity, Innovation, Rigorousness, and Efficiency" is definitely the persistent conception of our corporation to the long-term to establish alongside one another with customers for mutual reciprocity and mutual profit for OEM Manufacturer Endotoxin Assay Kit - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo , The product will supply to all over the world, such as: Boston, South Africa, Paris, Our qualified engineering team will usually be prepared to serve you for consultation and feedback. We are able to also deliver you with absolutely free samples to meet your needs. Best efforts might be made to offer you the ideal service and products. For anyone who is interested in our company and items, please make contact with us by sending us emails or contact us right away. In order to know our solutions and organization. ar more, you can come to our factory to determine it. We are going to usually welcome guests from around the globe to our corporation. o create small business relations with us. Please really feel no cost to speak to us for enterprise. nd we believe we are going to share the most effective trading practical experience with all our merchants.
  • The product classification is very detailed that can be very accurate to meet our demand, a professional wholesaler.
    5 Stars By Camille from Borussia Dortmund - 2017.03.08 14:45
    Although we are a small company, we are also respected. Reliable quality, sincere service and good credit, we are honored to be able to work with you!
    5 Stars By Bruno Cabrera from Swaziland - 2017.03.28 12:22

    Leave Your Messages

    Related products

    • Quality Inspection for Endotoxin Kits - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Quality Inspection for Endotoxin Kits - Beta-g...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Manufacturing Companies for Bacteria Endotoxin Test - Pyrogen-free Pipette tips and Consumables – Bioendo

      Manufacturing Companies for Bacteria Endotoxin ...

      Pyrogen-free Pipette tips and tip box 1. Product information We offer various low endotoxin, pyrogen-free accessories,includes Water for Bacterial Endotoxins Test, endotoxin-free test tubes, pyrogen-free pipette tips, pyroegn-free microplates for your operation. High quality depyrogenated and low endotoxin level consumables to ensure the success of your endotoxin assays. Pyrogen-free pipette tips are certified to contain <0.001 EU/ml endotoxin. The tips allow more flexibility with diffe...

    • Quality Inspection for Endotoxin Kits - Endotoxin-free Glass Test Tubes – Bioendo

      Quality Inspection for Endotoxin Kits - Endoto...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • China Gold Supplier for Bacteria Producing Endotoxin - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      China Gold Supplier for Bacteria Producing Endo...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • High definition Kinetic chromogenic LAL Assay - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo

      High definition Kinetic chromogenic LAL Assay -...

       Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay) The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit mee...

    • Factory Supply LAL Turbidimetric assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      Factory Supply LAL Turbidimetric assay - Bioen...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...