Just about every member from our large efficiency income crew values customers' wants and enterprise communication for Bacterial Endotoxin Test As Per Indian Pharmacopoeia, Endotoxin Gel Clot Method, Chromogenic Endotoxin Testing, Should you be fascinated in any of our products and services, remember to do not hesitate to make contact with us. We're ready to reply you inside of 24 several hours soon after receipt of one's ask for and also to develop mutual un-limited advantages and organization in around potential.
OEM Manufacturer BET Test Procedure - Rapid Gel Clot 10 Samples Kit – Bioendo Detail:

Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit)
1. Product Information

Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedures are very convenient, additional experimental equipment are required. It is a convenient and rapid way to detect endotoxin in especial suitable for water or dialysate.

20190819091605_48802

2. Product Parameter

Sensitivity Range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5EU/ml

10 sample tests in the kit. 

Assay time: less than 30 minutes

3. Product Application

Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate as well as do quickly endotoxin detection in life science research.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Description

Kit Contents

Sensitivity

EU/ml

Reaction Time

minutes

RG10025003

BioendoTM Rapid Gel Clot Endotoxin Assay Kit, 10 Samples Kit

10 SPL Tubes;

10 PPC Tubes;

10 Endotoxin-free Sample Bottles;

10 Packs of (3pcs Transfer Pipettes)

0.03

≤60

RG10025006

0.06

≤60

RG100250125

0.125

≤45

RG10025025

0.25

≤30

RG10025050

0.5

≤30

Kit configuration: 
Bioendo Rapid Gel Clot Endotoxin Assay Kit contains: 
10 SPL Tube, 10 PPC Tube, 10 Endotoxin-free Sample Bottle, 10 Pack of Transfer Pipette 3 pieces.
Simple and convenient procedure in the dilution of control standard endotoxin. Endotoxin free sample container and pyrogen free transfer pipette is required, Sophisticated instruments are required, recommend Bioendo Dry heat incubator TAL-MT use in the procedure of incubation.   

Product detail pictures:

OEM Manufacturer BET Test Procedure - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures

OEM Manufacturer BET Test Procedure - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures

OEM Manufacturer BET Test Procedure - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures

OEM Manufacturer BET Test Procedure - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures


Related Product Guide:

No matter new customer or old customer, We believe in long term and trusted relationship for OEM Manufacturer BET Test Procedure - Rapid Gel Clot 10 Samples Kit – Bioendo , The product will supply to all over the world, such as: Latvia, Poland, Malaysia, Each product is carefully made, it will make you satisfied. Our merchandise in the production process have got strictly monitored, because it is only to supply you the best quality, we'll feel confident. High production costs but low prices for our long-term cooperation. You can have a variety choices and the value of all types are same reliable. If you have any question, do not hesitate to ask us.
  • Problems can be quickly and effectively resolved, it is worth to be trust and working together.
    5 Stars By Mamie from Tunisia - 2017.12.31 14:53
    The sales person is professional and responsible, warm and polite, we had a pleasant conversation and no language barriers on communication.
    5 Stars By Josephine from Riyadh - 2018.09.08 17:09

    Leave Your Messages

    Related products

    • Low price for Pipettor tip box - Single-Channel Mechanical Pipettor – Bioendo

      Low price for Pipettor tip box - Single-Channe...

      Single-Channel Mechanical Pipettor   1. Product Information Single channel mechanical pipette is ideal tool to support endotoxin detection with Lyophilized Amebocyte Lysate which covers gel-clot technique, kinetic turbidimetric technique, kinetic chromogenic technique, and end-point chromogenic technique. All pipettors are produced by following ISO8655 – 2:2002. The quality control involves gravimetric testing of each pipette with distilled water at 22℃.   2. Product Features: - ...

    • Factory source Advantage Of LAL Test - Endotoxin Assay and (1,3)-ß-D-glucan assay software – Bioendo

      Factory source Advantage Of LAL Test - Endotox...

      Endotoxin and (1,3)-ß-D-glucan assay software 1. Product information Endotoxin and (1,3)-ß-D-glucan assay software is a powerful kinetic data analysis software,which gives the user data acquisition and processing of the maximum flexibility. Features: • Apply to Endotoxin assay,(1,3)-ß-D-glucan assay and ELISA data analysis • With standard version and clinical diagnostic version for the different user groups. • Data could be output transitions and connected to the LIS system. • Customizabl...

    • Factory Free sample Coagulation Gel - Rapid Gel Clot 10 Samples Kit – Bioendo

      Factory Free sample Coagulation Gel - Rapid Ge...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Wholesale depyrogenation is a 3-log reduction in endotoxin content - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Wholesale depyrogenation is a 3-log reduction i...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • High definition Control Standard Endotoxin Preparation - Depyrogenated Sample Bottles ( Endotoxin Free ) – Bioendo

      High definition Control Standard Endotoxin Prep...

      Depyrogenated Sample Container 1. Product information We offer various of low endotoxin, pyrogen free accessories products,includes Water for Bacterial Endotoxins Test, pyrogen-free test tubes, pyrogen-free pipettor tips, microplates and sample bottles for your conveniences. High quality depyrogenated low endotoxin pyrogen free products insure the success of your experiments. Depyrogenated (Endotoxin Free) Sample container(endotoxin free bottle, pyrogen free bottle, pyrogen free sample bot...

    • Low price for Endotoxin Free Tube - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Low price for Endotoxin Free Tube - Pyrogen-fr...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...