OEM China BET Testing - Compact Modular Dry Heat Incubator – Bioendo


Product Detail

Related Video

Feedback (2)

Sticking towards the theory of "Super Good quality, Satisfactory service" ,We are striving to become a superb business enterprise partner of you for LAL test for pyrogens, Endotoxin Detection Assay, Depyrogenated tips, If you are interested in any of our products and services, please don't hesitate to contact us. We are ready to reply you within 24 hours after receipt of your request and to create mutual un-limited benefits and business in near future.
OEM China BET Testing - Compact Modular Dry Heat Incubator – Bioendo Detail:

Dry Heat Incubator

1. Product description:

Dry Heat Incubator TAL-M2 is amicroprocessor-controlled device, high precision of temperature control, samplepreparation parallelism, as an alternative to the traditional water bathdevice. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules. TAL- M2 A Dry bath incubator Can achieve two independent heating modules, thermostats, unique combo designed to meet the needs of more experimental.

2. Product features

1, LCD display, simple interface.

2, high heating speed, uniformheating, accurate temperature control, high stability, low energy consumptionand no noise.

3, Built in temperature calibrationfunction, automatic fault detection and buzzer alarm function.

4, Built in over-temperatureprotection device, safe and reliable use, prolong the service life of themachine.

5, product design, compact and tight,small occupied space, freer and easier.

6, Various blocks for convenientreplacement, cleaning and disinfection.

7,It Can achieve two independentheating modules, thermostats, unique combo designed to meet the needs of moreexperimental.

dry bath double control, dry incubator doublemodule, limulus polyphemus blue blood, tal kinetic chromogenic method, talendotoxin kit

Product Name & Descriptions

TAL-M2 Dry heat incubator

(single heating module);

One modular total 60 holes for mass test in pharmaceuticals application.

Temperature control Range Ambient+5℃ ~ 150℃
Temperature setting range Ambient+5℃ ~ 150℃
Temperature rising time ≤ 30min (from 20℃ rise to 150℃), rise to 37deg C in about 60s.
Temperature Stability @100~150℃ ≤±1℃
Temperature Stability @40~100℃ ≤±0.5℃
Temperature Uniformity @40℃ ±0.3℃
Modular temperature uniformity ±0.5℃
Displayed Temperature Precision 0.1℃
Temperature Control time 99h59min
Fuse protector 250v, 3A/6A, Φ5×20
Highest Temperature 150℃
Power supply AC220V/AC110V, 50/60Hz, 400W
Dimension D260*W220*H95mm

 


Product detail pictures:

OEM China BET Testing - Compact Modular Dry Heat Incubator – Bioendo detail pictures

OEM China BET Testing - Compact Modular Dry Heat Incubator – Bioendo detail pictures

OEM China BET Testing - Compact Modular Dry Heat Incubator – Bioendo detail pictures


Related Product Guide:

We thinks what customers think, the urgency of urgency to act in the interests of a customer position of principle, allowing for better quality, lower processing costs, prices are more reasonable, won the new and old customers the support and affirmation for OEM China BET Testing - Compact Modular Dry Heat Incubator – Bioendo , The product will supply to all over the world, such as: Philadelphia, Singapore, Swiss, Wide selection and fast delivery for you! Our philosophy: Good quality, great service, keep improving. We are looking forward that more and more oversea friends join in our family for further development near the future!
  • Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
    5 Stars By Nancy from luzern - 2017.03.08 14:45
    The enterprise has a strong capital and competitive power, product is sufficient, reliable, so we have no worries on cooperating with them.
    5 Stars By Athena from panama - 2018.06.30 17:29

    Leave Your Messages

    Related products

    • Fixed Competitive Price Endotoxin Measurement - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo

      Fixed Competitive Price Endotoxin Measurement -...

      LAL Reagent Water ( Water for Bacterial Endotoxins Test / Water for BET / TAL Reagnt Water )  1. Product Information LAL Reagent Water (Water for Bacterial Endotoxins Test or BET Water or Water for BET )is specially processed super-purified endotoxin free water is used for Endotoxin test. Its endotoxin concentration is less than 0.005 EU/ml. Various packages, such as 2ml, 10ml, 50ml, 100ml and 500ml per unit, are provided for users’ convenience. LAL Reagent Water (Water for BET) could...

    • Trending Products Bacterial Endotoxin Test For Water For Injection - Depyrogenated Sample Bottles ( Endotoxin Free ) – Bioendo

      Trending Products Bacterial Endotoxin Test For ...

      Depyrogenated Sample Container 1. Product information We offer various of low endotoxin, pyrogen free accessories products,includes Water for Bacterial Endotoxins Test, pyrogen-free test tubes, pyrogen-free pipettor tips, microplates and sample bottles for your conveniences. High quality depyrogenated low endotoxin pyrogen free products insure the success of your experiments. Depyrogenated (Endotoxin Free) Sample container(endotoxin free bottle, pyrogen free bottle, pyrogen free sample bot...

    • 2022 China New Design Kinetic Turbidimetric Assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      2022 China New Design Kinetic Turbidimetric Ass...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • Discountable price Endotoxin Microbiology - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Discountable price Endotoxin Microbiology - Py...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

    • Wholesale Kinetic Turbidimetric TAL Test - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      Wholesale Kinetic Turbidimetric TAL Test - Kin...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...

    • Factory wholesale Endotoxin Gel Clot - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo

      Factory wholesale Endotoxin Gel Clot - Gel Clo...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoule, you could add sample to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to avoi...