New Fashion Design for Bacterial Endotoxin Test Method Validation Protocol - Endotoxin-free Glass Test Tubes – Bioendo


Product Detail

Related Video

Feedback (2)

We take "customer-friendly, quality-oriented, integrative, innovative" as objectives. "Truth and honesty" is our administration ideal for Endotoxin free glass tube, Bacterial Endotoxin Test Procedure, BET Test Principle, We are looking forward to forming successful business relationship with new clients in the near future!
New Fashion Design for Bacterial Endotoxin Test Method Validation Protocol - Endotoxin-free Glass Test Tubes – Bioendo Detail:

Endotoxin-free Glass Test Tubes

 

1. Product Information

Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used for kinetic tube reader.

 

2. Product Parameter

Endotoxin level ≤0.005EU/ml

3. Product Features and Application

Made with borosilicate glass. Cover with aluminum caps. Various size suitable for gel clot reactions, sample dilutions and control standard endotoxin dilutions.

 Catalog No.  

Size mm

(outside diameter)

With

Aluminum Caps

Package

tubes/pack

T087565

Φ8×75

No

65

T107505C

Φ10×75

Yes

5

T107540

 Φ10×75

No

40

T127505C

Φ12×75

Yes

5

T127525

 Φ12×75

No

25

T1310005C

Φ13×100

Yes

5

T1310018

 Φ13×100

No

18

Why would I use endotoxin-free test consumables?

such as endotoxin free tubes; pyrogen-free tips; pyrogen-free microplates; endotoxin free sample bottles; 

According to China Pharmacopoeia, the utensils needed in the procedure of endotoxin test assay, such as sample vessel, dilution and reaction tubes, pipette tips, have to choose endotoxin free consumables. the utensils needed for the experiment need to be processed to remove possible exogenous endotoxins. If the endotoxin is not removed, it will interfere with the result of endotoxin assay.

 


Product detail pictures:

New Fashion Design for Bacterial Endotoxin Test Method Validation Protocol - Endotoxin-free Glass Test Tubes – Bioendo detail pictures

New Fashion Design for Bacterial Endotoxin Test Method Validation Protocol - Endotoxin-free Glass Test Tubes – Bioendo detail pictures

New Fashion Design for Bacterial Endotoxin Test Method Validation Protocol - Endotoxin-free Glass Test Tubes – Bioendo detail pictures


Related Product Guide:

"Sincerity, Innovation, Rigorousness, and Efficiency" could be the persistent conception of our enterprise to the long-term to produce together with clients for mutual reciprocity and mutual profit for New Fashion Design for Bacterial Endotoxin Test Method Validation Protocol - Endotoxin-free Glass Test Tubes – Bioendo , The product will supply to all over the world, such as: Philippines, Czech republic, Cairo, Furthermore, all of our products are manufactured with advanced equipment and strict QC procedures in order to ensure high quality. If you are interested in any of our products, please don't hesitate to contact us. We will do our best to meet your needs.
  • Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.
    5 Stars By Patricia from Ghana - 2018.09.23 18:44
    The company can keep up with the changes in this industry market, product updates fast and the price is cheap, this is our second cooperation, it's good.
    5 Stars By Julia from Brasilia - 2018.09.21 11:44

    Leave Your Messages

    Related products

    • Manufacturer for LAL reagent manufacturer - Rapid Gel Clot single test kit – Bioendo

      Manufacturer for LAL reagent manufacturer - Ra...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • OEM China Endotoxin Detection Kit - Control Standard Endotoxin (CSE) – Bioendo

      OEM China Endotoxin Detection Kit - Control St...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • Top Suppliers Dry Heat Sterilizer Validation - Endotoxin Assay and (1,3)-ß-D-glucan assay software – Bioendo

      Top Suppliers Dry Heat Sterilizer Validation -...

      Endotoxin and (1,3)-ß-D-glucan assay software 1. Product information Endotoxin and (1,3)-ß-D-glucan assay software is a powerful kinetic data analysis software,which gives the user data acquisition and processing of the maximum flexibility. Features: • Apply to Endotoxin assay,(1,3)-ß-D-glucan assay and ELISA data analysis • With standard version and clinical diagnostic version for the different user groups. • Data could be output transitions and connected to the LIS system. • Customizabl...

    • Manufacturer of Endotoxin LAL Testing - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo

      Manufacturer of Endotoxin LAL Testing - LAL Re...

      LAL Reagent Water ( Water for Bacterial Endotoxins Test / Water for BET / TAL Reagnt Water )  1. Product Information LAL Reagent Water (Water for Bacterial Endotoxins Test or BET Water or Water for BET )is specially processed super-purified endotoxin free water is used for Endotoxin test. Its endotoxin concentration is less than 0.005 EU/ml. Various packages, such as 2ml, 10ml, 50ml, 100ml and 500ml per unit, are provided for users’ convenience. LAL Reagent Water (Water for BET) could...

    • 2022 New Style Endotoxin Assay Kits - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      2022 New Style Endotoxin Assay Kits - Pyrogen-...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

    • Excellent quality Turbidimetric endotoxin assays - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      Excellent quality Turbidimetric endotoxin assay...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...