New Fashion Design for Bacterial Endotoxin Test Method Validation Protocol - Endotoxin-free Glass Test Tubes – Bioendo


Product Detail

Related Video

Feedback (2)

We always believe that one's character decides products' quality, the details decides products' quality ,with the REALISTIC,EFFICIENT AND INNOVATIVE team spirit for Bacterial Endotoxin Test Calculation, Endotoxin Blood Test, Gel Clot Endotoxin Test, Our professional technical team will be wholeheartedly at your service. We sincerely welcome you to visit our website and company and send us your inquiry.
New Fashion Design for Bacterial Endotoxin Test Method Validation Protocol - Endotoxin-free Glass Test Tubes – Bioendo Detail:

Endotoxin-free Glass Test Tubes

 

1. Product Information

Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used for kinetic tube reader.

 

2. Product Parameter

Endotoxin level ≤0.005EU/ml

3. Product Features and Application

Made with borosilicate glass. Cover with aluminum caps. Various size suitable for gel clot reactions, sample dilutions and control standard endotoxin dilutions.

 Catalog No.  

Size mm

(outside diameter)

With

Aluminum Caps

Package

tubes/pack

T087565

Φ8×75

No

65

T107505C

Φ10×75

Yes

5

T107540

 Φ10×75

No

40

T127505C

Φ12×75

Yes

5

T127525

 Φ12×75

No

25

T1310005C

Φ13×100

Yes

5

T1310018

 Φ13×100

No

18

Why would I use endotoxin-free test consumables?

such as endotoxin free tubes; pyrogen-free tips; pyrogen-free microplates; endotoxin free sample bottles; 

According to China Pharmacopoeia, the utensils needed in the procedure of endotoxin test assay, such as sample vessel, dilution and reaction tubes, pipette tips, have to choose endotoxin free consumables. the utensils needed for the experiment need to be processed to remove possible exogenous endotoxins. If the endotoxin is not removed, it will interfere with the result of endotoxin assay.

 


Product detail pictures:

New Fashion Design for Bacterial Endotoxin Test Method Validation Protocol - Endotoxin-free Glass Test Tubes – Bioendo detail pictures

New Fashion Design for Bacterial Endotoxin Test Method Validation Protocol - Endotoxin-free Glass Test Tubes – Bioendo detail pictures

New Fashion Design for Bacterial Endotoxin Test Method Validation Protocol - Endotoxin-free Glass Test Tubes – Bioendo detail pictures


Related Product Guide:

Our rewards are lower costs,dynamic profits team,specialised QC,potent factories,high-quality services for New Fashion Design for Bacterial Endotoxin Test Method Validation Protocol - Endotoxin-free Glass Test Tubes – Bioendo , The product will supply to all over the world, such as: United Arab emirates, Houston, Bangladesh, Our company always provides good quality and reasonable price for our customers. In our efforts, we already have many shops in Guangzhou and our products have won praise from customers worldwide. Our mission has always been simple: To delight our customers with best quality hair products and deliver on time. Welcome new and old customers to contact us for the future long term business relationships.
  • The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
    5 Stars By Eleanore from USA - 2017.02.28 14:19
    A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Nicci Hackner from Oslo - 2018.12.25 12:43

    Leave Your Messages

    Related products

    • Factory wholesale TAL Reagent Water - Rapid Gel Clot single test kit – Bioendo

      Factory wholesale TAL Reagent Water - Rapid Ge...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • Low MOQ for Bacterial Endotoxins Test Usp - Endotoxin-free Glass Test Tubes – Bioendo

      Low MOQ for Bacterial Endotoxins Test Usp - En...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • PriceList for LAL Method - Rapid Gel Clot 10 Samples Kit – Bioendo

      PriceList for LAL Method - Rapid Gel Clot 10 S...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Reasonable price Turbidimetric LAL assay - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      Reasonable price Turbidimetric LAL assay - Kin...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...

    • Fixed Competitive Price Endotoxin Measurement - Endotoxin-free Glass Test Tubes – Bioendo

      Fixed Competitive Price Endotoxin Measurement -...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • Factory Cheap Hot limulus amebocyte - Eight-channel Mechanical Pipette – Bioendo

      Factory Cheap Hot limulus amebocyte - Eight-ch...

      Eight-Channel Mechanical Pipettor 1. Product information All multi-channel mechanical pipettor have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22℃. The multichannel mechanical pipettor is idea for the detectionof bacterial endotoxin lal endotoxin testing by kinetic turbidimetric andkinetic chromogenic method. - Eight-Channel Mechanical Pipettor is available for stand...