Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo


Product Detail

Related Video

Feedback (2)

We insist on offering high-quality production with great enterprise concept, honest product sales and also the finest and fast service. it will bring you not only the superior quality solution and huge profit, but the most significant should be to occupy the endless market for LAL Turbidimetric test, limulus lysate, Kinetic chromogenic LAL Assay, Welcome you to join us together to make your business easier. We are always your best partner when you want to have your own business.
Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo Detail:

Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule

1. Product Information

Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoule, you could add sample to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to avoid waste. Endotoxin free tubes for the dilution of Lyophilized CSE is necessary. Operation of endotoxin detection use Bioendo Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule conforms to the USP, the EP. 

2. Product Parameter

Gel clot assay single test glass ampoule.

Sensitivities:  0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25 EU/ml

3.Product Feature and Application

Single step endotoxin detection,

without expensive endotoxin assay instrument.

Suitable for end-product endotoxin testing before product released.

Product sensitivity standardized according to US Pharmacopoeia criterion and China Pharmacopoeia criterion.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from lysate of amebocytes (white blood cells) from the horseshoe crab.

Catalog No.

Sensitivity EU/ml

Description

Kit Contents

GS44010030

0.03

Bioendo Gel Clot Endotoxin Test Kit, (Single Test in Ampoule, 44Tests/Kit),

44 Gel Clot Lyophilized Amebocyte Lysate;

1 CSE 10A;

5 Water for BET , 2ml/vial

GS44010060

0.06

GS44010125

0.125

GS44010250

0.25

GS44010500

0.5

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis, MSDS.

Why the most selected gel clot assay kit GS44:

1. The most economical and commonly used test reagent for endotoxin detection.

2. Single test in a vial for one stepping reduce the risk of contamination.

3. Gel clot assay single test glass vial no need sophisticated microplate reader.

4. Saving endotoxin free tube when using GS44 series to test endotoxins in the procedure of endotoxin test assay’s operation.

Related products in the endotoxin test assay:
Water for Bacterial Endotoxins Test (BET),  Recommend TRW02, TRW50 or TRW100
Endotoxin free glass tube ( dilution tube ),  Recommend T1310018
Pyrogen free tips,  Recommend PT25096 or PT100096
Pipettor, Recommend PSB0220
Test Tube Rack,
Incubation Instrument (Water Bath or Dry Heat Incubator ), Recommend Dry Heat Incubator TAL-M2
Vortex Mixter, Recommend VXH.
Control Standard Endotoxin, CSE10A.

Product detail pictures:

Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo detail pictures

Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo detail pictures

Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo detail pictures

Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo detail pictures


Related Product Guide:

We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate inside our success for Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo , The product will supply to all over the world, such as: Mombasa, Palestine, Sydney, Satisfaction and good credit to every customer is our priority. We focus on every detail of order processing for customers till they have received safe and sound products with good logistics service and economical cost. Depending on this, our products are sold very well in the countries in Africa, the Mid-East and Southeast Asia.
  • We feel easy to cooperate with this company, the supplier is very responsible, thanks.There will be more in-depth cooperation.
    5 Stars By Louis from Austria - 2017.03.07 13:42
    The enterprise has a strong capital and competitive power, product is sufficient, reliable, so we have no worries on cooperating with them.
    5 Stars By Andy from Gabon - 2018.06.21 17:11

    Leave Your Messages

    Related products

    • High definition Chromogenic Endotoxin Testing – Endpoint Chromogenic Kit EC64405 – Bioendo

      High definition Chromogenic Endotoxin Testing &...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • Top Suppliers Endotoxin LAL Test Kit - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Top Suppliers Endotoxin LAL Test Kit - Pyrogen...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog ...

    • China Cheap price TAL test - Rapid Gel Clot single test kit – Bioendo

      China Cheap price TAL test - Rapid Gel Clot si...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • 100% Original Endotoxin free glass tube - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      100% Original Endotoxin free glass tube - Pyro...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • Chinese wholesale Chromogenic endotoxin assay - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo

      Chinese wholesale Chromogenic endotoxin assay -...

       Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay) The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit mee...

    • 2022 Good Quality TAL assay kit - Mini Dry Heat Incubator – Bioendo

      2022 Good Quality TAL assay kit - Mini Dry Hea...

      Dry heat incubator single module 1. Product information  The Mini Dry Heat Incubator is a micro-processor controlled heating block with semi conductor heating technology.It adapts onboard use, smart, light and convenient for movement, suit for any kind of occasions. Especially good for the incubation of the gel clot LAL assay, LAL chromogenic endpoint assay incubation. 2. Product features 1. Unique designed. Smart and light, convenient movement, suit for various occasions. 2. LCD simultaneou...