Manufacturer for LAL reagent manufacturer - Kinetic Incubating Microplate Reader ELX808IULALXH – Bioendo


Product Detail

Related Video

Feedback (2)

We constantly think and practice corresponding to the change of circumstance, and grow up. We aim at the achievement of a richer mind and body along with the living for Chromogenic LAL Endotoxin Assay Kit, BET Endotoxin Test, Kinetic chromogenic LAL test kit, Therefore, we can meet different inquiries from different consumers. You should find our web page to check additional info from our products.
Manufacturer for LAL reagent manufacturer - Kinetic Incubating Microplate Reader ELX808IULALXH – Bioendo Detail:

Kinetic Incubating Microplate Reader

1. Product information

Kinetic Incubating Microplate Reader Elx808 is a multifunctional kinetic reader designed for bacterial endotoxin assay, fungi (1,3)-ß-D-glucan assay and ELISA assays. The reader is a highly accurate, easy to use instrument for kinetic turbidimetric LAL/TAL assay, kinetic chromogenic LAL test and endpoint chromogenic LAL assay.  Compare to kinetic incubating tube reader,the microplate reader is more efficient and is possible to be scaled up toautomatic performance.

2. Instrument parameters

- wavelength range of 340-900 nm, suitable for ultraviolet and visible light detection.

- 6 filter wheel, standard configuration with 5 filters (340,405, 490, 540 and 630 nm).

- temperature control range: room temperature+5℃ to 50℃

- standard curve linear correlation coefficient: |r|≥0.99

- assay repeatability: CV≤5%

- 96 tests per plate

3.  Application range:

- Bacterial endotoxin (pyrogen) assay of drugs, vaccines, Water for Injection medical devices, infusion, transfusion related devices dialysate,dialysis water endotoxin testing cell suspension, cell culture media, cell culture related products recombinant protein, nucleic acid and other molecular biological products

-Endotoxin level monitoring during production: pharmaceutical raw materials, intermediate products, end product endotoxin daily monitoring.

-Clinical diagnostic of sepsis and invasive fungi disease:plasma, serum, urine, cerebrospinal fluid endotoxin and (1,3)-beta-D-glucandetection.

Catalog No.

Description

KPR808IULAL

Kinetic incubating microplate reader Elx808  for Endotoxin and ß-glucan detection

20180903103214_47978

Please contact sales@houshiji.com to order the LAL reagents endotoxin detection kit.

There is no minimal order volume required.

The price depends on the order quantity. We provide distributor discount for our partners.

Bioendo provide professional transport services for sophisticated instruments to make sure safety international transportation.

 

Kinetic microplate incubating reader +

Quantitative Lysate reagent +

Pyrogen free microplate +

Pyrogen free tips.


Product detail pictures:

Manufacturer for LAL reagent manufacturer - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo detail pictures

Manufacturer for LAL reagent manufacturer - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo detail pictures

Manufacturer for LAL reagent manufacturer - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo detail pictures


Related Product Guide:

Our primary intention should be to offer our clientele a serious and responsible enterprise relationship, delivering personalized attention to all of them for Manufacturer for LAL reagent manufacturer - Kinetic Incubating Microplate Reader ELX808IULALXH – Bioendo , The product will supply to all over the world, such as: Korea, Rio de Janeiro, Lisbon, Our items have national accreditation requirements for qualified, high quality products, affordable value, was welcomed by people today all over the world. Our goods will continue to enhance within the order and look forward to cooperation with you, Should any of these products be of interest to you, please letus know. We are going to be content to offer you a quotation up on receipt of your detailed needs.
  • We have been appreciated the Chinese manufacturing, this time also did not let us disappoint,good job!
    5 Stars By Fernando from Malta - 2018.12.10 19:03
    It can be said that this is a best producer we encountered in China in this industry, we feel lucky to work with so excellent manufacturer.
    5 Stars By Betty from Canada - 2017.08.16 13:39

    Leave Your Messages

    Related products

    • Manufacturer for LAL reagent manufacturer - Single-Channel Mechanical Pipettes (Semi-sterile) – Bioendo

      Manufacturer for LAL reagent manufacturer - Si...

      Single-Channel Mechanical Pipettes (Semi-sterile)   1. Product Information The Single-Channel Mechanical Pipettes (Semi-sterile) is adjustable, which could be used to dispense liquid precisely. Measuring volume of our Single-Channel Mechanical Pipettes (Semi-sterile) ranges from 0.1μL to 5mL. Products are produced based on ISO8655/DIN12650. It could be widely employed on endotoxin detection, etc..   2. Product Features - Light weight, economic - The pipettes cover volume range from 0.1μL to 5...

    • Quality Inspection for Endotoxin Kits - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Quality Inspection for Endotoxin Kits - Pyroge...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

    • Manufacturer for LAL reagent manufacturer - Vortex Mixer – Bioendo

      Manufacturer for LAL reagent manufacturer - Vo...

      Vortex mixer 1. Product information The Vortex mixer widely used in life science, physical and chemicalanalysis fields, for vigorous re-suspension of cells or chemical pelletsin tubes up to 15 ml. It is good for the dilution and mixing the Control Standard Endotoxin solution in endotoxin assay with gel clot method, kinetic chromogenic method, kinetic turbidimetric method and end-point chromogenic method. 2. Features - Touch and continuous operations - with wide speed range of 0-2500rpm,st...

    • China Cheap price LAL gel clot method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G17 – Bioendo

      China Cheap price LAL gel clot method - Gel Cl...

      Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial, G17 series 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial is the Lyophilized Amebocyte Lysate reagent which choose gel clot technique to detect endotoxin or pyrogen. As the widespread method, gel-clot test for endotoxin is simple and does not require specific and expensive instrument. Bioendo provides Gel Clot Lyophilized Amebocyte Lysate reagent in 1.7ml per vial. 2. Product Parameter Sensitivity range: 0....

    • Best Price for Endotoxin Indicator For Depyrogenation Usp - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      Best Price for Endotoxin Indicator For Depyroge...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • Online Exporter Endotoxin Detection System - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Online Exporter Endotoxin Detection System - P...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...