Hot New Products Rapid Gel Clot Endotoxin Test Kit For Water And Dialysate - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo


Product Detail

Related Video

Feedback (2)

We always continually provide you with the most conscientious customer service, and the widest variety of designs and styles with finest materials. These efforts include the availability of customized designs with speed and dispatch for Endotoxin Assay Kit, TAL gel clot, Endotoxin Gel Clot, For further inquires please do not hesitate to contact us. Thank you - Your support continuously inspires us.
Hot New Products Rapid Gel Clot Endotoxin Test Kit For Water And Dialysate - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo Detail:

Gel Clot Method Lyophilized Amebocyte Lysate Multi-test Vial G52 series

1. Product Information

Gel Clot method Lyophilized Amebocyte Lysate Multi-test Vial is the Lyophilized Amebocyte Lysate reagent which select and use gel clot technique to detect endotoxin or pyrogen.

As the widespread method, gel-clot test for endotoxin is simple and does not require specific and expensive instrument. Bioendo provides Gel Clot Lyophilized Amebocyte Lysate reagent in 5.2ml per vial.

2. Product Parameters

Sensitivity range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5 EU/ml 

3. Product Application

End-product endotoxin (pyrogen) qualification, waterfor injection endotoxin assay, raw material endotoxin testing or endotoxinlevel monitoring during manufacturing process for pharmaceutical companies ormedical devices manufacturers.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from lysate of amebocytes (white blood cells) from the horseshoe crab.

Gel clot method LAL assay, reconstituted lysate reagent get at least 50 tests per vial:
Catalog Number Sensitivity (EU/ml or IU/ml) ml/vial Tests/Vial Vials/Pack
G520030 0.03 5.2 50 10
G520060 0.06 5.2 50 10
G520125 0.125 5.2 50 10
G520250 0.25 5.2 50 10
G520500 0.5 5.2 50 10

Product condition

The Lyophilized Amebocyte Lysate reagent sensitivity and the Control Standard Endotoxin potency are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte reagent kits come with product instruction, Certificate of Analysis, MSDS.

 

What is the difference between single test and multiple test?

● Single test: reconstitute the single test lysate reagent by BET water in the glass vial or glass ampoule.

● Multi-test: reconstitute the lysate reagent with BET water, and then add marked amount of lysate reagent following COA to the reaction tube or well plate for use. There is no difference in the sample pre-processing procedure; according to the amount of testing used, the sample size used for a single test is larger than the sample size used for multiple tests.

 

Why the most selected gel clot assay kit G52:

1. Multi test reagent for endotoxin detection in the applications of certain samples’ endotoxin detection.

2. G52 series of Gel clot assay multi test glass vial no need sophisticated microplate reader. Procedure of incubation by water bath or dry heat incubator.

3. High end quality of endotoxin free tube (<0.005EU/ml) and High quality of pyrogen free tips (<0.005EU/ml) as the guaranteed consumables to ensure the correct result.

Related products in the endotoxin test assay:
Water for Bacterial Endotoxins Test (BET),  Recommend TRW50 or TRW100
Endotoxin free glass tube ( dilution tube ),  Recommend T1310018 and T107540
Pyrogen free tips,  Recommend PT25096 or PT100096
Pipettor, Recommend PSB0220
Test Tube Rack,
Incubation Instrument (Water Bath or Dry Heat Incubator ), Recommend Dry Heat Incubator TAL-M2
Vortex Mixter, Recommend VXH.
Control Standard Endotoxin, CSE10V.

Product detail pictures:

Hot New Products Rapid Gel Clot Endotoxin Test Kit For Water And Dialysate - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures

Hot New Products Rapid Gel Clot Endotoxin Test Kit For Water And Dialysate - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures

Hot New Products Rapid Gel Clot Endotoxin Test Kit For Water And Dialysate - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures

Hot New Products Rapid Gel Clot Endotoxin Test Kit For Water And Dialysate - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures

Hot New Products Rapid Gel Clot Endotoxin Test Kit For Water And Dialysate - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures


Related Product Guide:

We not only will try our greatest to present fantastic expert services to each purchaser, but also are ready to receive any suggestion offered by our prospects for Hot New Products Rapid Gel Clot Endotoxin Test Kit For Water And Dialysate - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo , The product will supply to all over the world, such as: Slovak Republic, Indonesia, Porto, During the development, our company has built a well-known brand. It is well highly acclaimed by our customers. OEM and ODM are accepted. We are looking forward to customers from all over the world to join us to a wild cooperation.
  • Staff is skilled, well-equipped, process is specification, products meet the requirements and delivery is guaranteed, a best partner!
    5 Stars By Dana from Tajikistan - 2018.11.02 11:11
    This company conforms to the market requirement and joins in the market competition by its high quality product, this is an enterprise that have Chinese spirit.
    5 Stars By Cornelia from Philippines - 2017.09.26 12:12

    Leave Your Messages

    Related products

    • OEM China Endotoxin Detection Kit - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      OEM China Endotoxin Detection Kit - Pyrogen-fr...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

    • Chinese Professional Chromogenic assays - Endpoint Chromogenic Kit EC64405 – Bioendo

      Chinese Professional Chromogenic assays - Endp...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • 2022 wholesale price TAL assay - Vortex Mixer – Bioendo

      2022 wholesale price TAL assay - Vortex Mixer ...

      Vortex mixer 1. Product information The Vortex mixer widely used in life science, physical and chemicalanalysis fields, for vigorous re-suspension of cells or chemical pelletsin tubes up to 15 ml. It is good for the dilution and mixing the Control Standard Endotoxin solution in endotoxin assay with gel clot method, kinetic chromogenic method, kinetic turbidimetric method and end-point chromogenic method. 2. Features - Touch and continuous operations - with wide speed range of 0-2500rpm,st...

    • Hot-selling Kinetic chromogenic LAL test kit - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo

      Hot-selling Kinetic chromogenic LAL test kit -...

       Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay) The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit mee...

    • Reasonable price Micro kinetic chromogenic endotoxin assay - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo

      Reasonable price Micro kinetic chromogenic endo...

       Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay) The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit mee...

    • Online Exporter Endotoxin Detection System - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      Online Exporter Endotoxin Detection System - P...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...