High Quality LAL Reagent - Rapid Gel Clot single test kit – Bioendo


Product Detail

Related Video

Feedback (2)

We have been committed to offering easy,time-saving and money-saving one-stop purchasing service of consumer for Dry heat tunnel validation by ECV, Endotoxin LAL Method, Bacterial Endotoxins Test, Our firm is dedicated to giving shoppers with significant and steady high quality goods at aggressive price tag, generating every single customer satisfied with our products and services.
High Quality LAL Reagent - Rapid Gel Clot single test kit – Bioendo Detail:

Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit)

1. Product Information

Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes.
Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures in the operation of rapid endotoxin assay, the whole operation not required sophisticated experimental equipment, incubation by a dry heat incubator. It is especial suitable for the endotoxins analysis in the water or dialysate.

20190819091605_48802

2. Product Parameter

Sensitivity Range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5EU/ml

One sample test in a kit. 

Assay time: less than 30 minutes. 

Catalog No.

Description

Kit Contents

Sensitivity

EU/ml

Reaction Time

minutes

RG025003

BioendoTM Rapid Gel Clot Endotoxin Assay Kit, One Sample Kit

1 SPL Tube;

1 PPC Tube;

1 Endotoxin-free Sample Bottle;

3 Pyrogen-free Pipettors;

0.03

≤60

RG025006

0.06

≤60

RG0250125

0.125

≤45

RG025025

0.25

≤30

RG025050

0.5

≤30

 

3. Kit Application

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit provide a kind of rapid endotoxin testing solution, the featured application in the field of dialysis. 

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab. In the operation procedure,  the dilution of control standard endotoxin is simple and convenient. Endotoxin free sample container and pyrogen free transfer pipette is required, Sophisticated instrument is not required, recommend Bioendo Dry heat incubator TAL-MT use in the procedure of incubation. 

Kit Configuration:

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit contains: 

1 piece of SPL Tube, 1 piece of PPC Tube, 1 piece of Endotoxin-free Sample Bottle. (endotoxin free top level), 

1 Pack of Transfer Pipette 3 pieces. (endotoxin free top level)


Product detail pictures:

High Quality LAL Reagent - Rapid Gel Clot single test kit – Bioendo detail pictures

High Quality LAL Reagent - Rapid Gel Clot single test kit – Bioendo detail pictures

High Quality LAL Reagent - Rapid Gel Clot single test kit – Bioendo detail pictures

High Quality LAL Reagent - Rapid Gel Clot single test kit – Bioendo detail pictures

High Quality LAL Reagent - Rapid Gel Clot single test kit – Bioendo detail pictures


Related Product Guide:

Trustworthy good quality and excellent credit score standing are our principles, which will help us at a top-ranking position. Adhering towards the tenet of "quality first, buyer supreme" for High Quality LAL Reagent - Rapid Gel Clot single test kit – Bioendo , The product will supply to all over the world, such as: Poland, Denver, New York, We maintain long-term efforts and self-criticism, which helps us and improvement constantly. We strive to improve customer efficiency to save costs for customers. We do our best to improve the quality of product. We will not live up to the historic opportunity of the times.
  • This is a reputable company, they have a high level of business management, good quality product and service, every cooperation is assured and delighted!
    5 Stars By Hedy from Turin - 2017.02.18 15:54
    Although we are a small company, we are also respected. Reliable quality, sincere service and good credit, we are honored to be able to work with you!
    5 Stars By Katherine from Bolivia - 2017.11.01 17:04

    Leave Your Messages

    Related products

    • High Performance Endotoxin Detection Method - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      High Performance Endotoxin Detection Method - ...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Factory source Advantage Of LAL Test - Single-Channel Mechanical Pipettor – Bioendo

      Factory source Advantage Of LAL Test - Single-...

      Single-Channel Mechanical Pipettor   1. Product Information Single channel mechanical pipette is ideal tool to support endotoxin detection with Lyophilized Amebocyte Lysate which covers gel-clot technique, kinetic turbidimetric technique, kinetic chromogenic technique, and end-point chromogenic technique. All pipettors are produced by following ISO8655 – 2:2002. The quality control involves gravimetric testing of each pipette with distilled water at 22℃.   2. Product Features: - ...

    • Wholesale Price China Bacterial Endotoxin Test By Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo

      Wholesale Price China Bacterial Endotoxin Test ...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoule, you could add sample to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to avoi...

    • Manufacturer for Chromogenic endotoxin detection - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      Manufacturer for Chromogenic endotoxin detectio...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...

    • Chinese Professional LAL test kit price - Single-Channel Mechanical Pipettor – Bioendo

      Chinese Professional LAL test kit price - Sing...

      Single-Channel Mechanical Pipettor   1. Product Information Single channel mechanical pipette is ideal tool to support endotoxin detection with Lyophilized Amebocyte Lysate which covers gel-clot technique, kinetic turbidimetric technique, kinetic chromogenic technique, and end-point chromogenic technique. All pipettors are produced by following ISO8655 – 2:2002. The quality control involves gravimetric testing of each pipette with distilled water at 22℃.   2. Product Features: - ...

    • PriceList for Pyrogen Free Tube - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo

      PriceList for Pyrogen Free Tube - Kinetic Incu...

      Kinetic Incubating Microplate Reader 1. Product information Kinetic Incubating Microplate Reader Elx808 is a multifunctional kinetic reader designed for bacterial endotoxin assay, fungi (1,3)-ß-D-glucan assay and ELISA assays. The reader is a highly accurate, easy to use instrument for kinetic turbidimetric LAL/TAL assay, kinetic chromogenic LAL test and endpoint chromogenic LAL assay.  Compare to kinetic incubating tube reader,the microplate reader is more efficient and is possible to be sc...