High definition Chromogenic Endotoxin Testing – Endpoint Chromogenic Kit EC64405 – Bioendo


Product Detail

Related Video

Feedback (2)

Trustworthy good quality and excellent credit score standing are our principles, which will help us at a top-ranking position. Adhering towards the tenet of "quality first, buyer supreme" for Endotoxin free reagent reservoir, Turbidimetric LAL test, Micro kinetic chromogenic endotoxin test kit, We sincerely welcome you appear to go to us. Hope now we have fantastic cooperation during the upcoming.
High definition Chromogenic Endotoxin Testing – Endpoint Chromogenic Kit EC64405 – Bioendo Detail:

End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling)

1. Product Information

End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin concentration of test sample could be calculated based on a standard curve.

2. Product parameter

Sensitivity Range: 0.01-0.1 EU/ml, matching assay time is about 46 minutes

                              0.1-1 EU/ml, matching assay time is about 16 minutes. 

3. Product Features and Application

End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is intended for use in the In Vitro detection and quantitation of gram-negative bacterial endotoxins. The colorless artificial peptide substrate solution is added into the mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. Yellow color develops if test sample contains endotoxin. Then use regular spectrophotometer or plate reader to read the absorbance at 405nm. End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is suitable for all kinds of biomedical samples such as protein, vaccine, plasmid, DNA, RNA endotoxin assay. 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Description

Kit Contents

Sensitivity

(EU/ml)

EC64405

 

Bioendo™ EC Endotoxin Test Kit (End-point Chromogenic Assay),

64 Tests/Kit

 

2 Lyophilized Amebocyte Lysate, 1.7ml/vial;

2 Water for BET, 50ml/vial;  

2 CSE;

4 Chromogenic Substrate, 1.7ml/vial;

0.1 – 1 EU/ml

EC64405S

0.01 – 0.1 EU/ml;

0.1 – 1 EU/m

Product Condition:

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

 

Does the End point endotoxin test kit need sophisticated microplate reader?

Bioendo EC64405 and EC64405S kit analysis the quantitative endotoxin results through regular microplate reader. 

End point chromogenic endotoxin test kit series:

Endotoxin Free Tube

Pyrogen Free Tips

Pyrogen Free Microplates

Regular Microplate reader

Matched Control standard endotoxin (CSE10V)

BET water use for reconstitution. 

 



Product detail pictures:


Related Product Guide:

All we do is always involved with our tenet " Consumer initial, Trust first, devoting within the food stuff packaging and environmental defense for High definition Chromogenic Endotoxin Testing – Endpoint Chromogenic Kit EC64405 – Bioendo , The product will supply to all over the world, such as: Sierra Leone, Austria, Bolivia, We are confident that we are able to provide you with opportunities and will be a valuable business partner of you. We look forward to working with you soon. Learn more about the types of products that we work with or contact us now directly with your inquiries. You are welcome to contact us anytime!
High Quality, High Efficiency, Creative and Integrity, worth having long-term cooperation! Looking forward to the future cooperation!
5 Stars By Adam from Bangladesh - 2018.07.26 16:51
The manufacturer gave us a big discount under the premise of ensuring the quality of products, thank you very much, we will select this company again.
5 Stars By Albert from Uzbekistan - 2018.09.21 11:01

Leave Your Messages

Related products

  • OEM Customized Bacterial Endotoxins Test - Control Standard Endotoxin (CSE) – Bioendo

    OEM Customized Bacterial Endotoxins Test - Con...

    Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

  • Factory Supply LAL Turbidimetric assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

    Factory Supply LAL Turbidimetric assay - Bioen...

    Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

  • PriceList for Kinetic chromogenic LAL Assay - Endpoint Chromogenic Kit EC64405 – Bioendo

    PriceList for Kinetic chromogenic LAL Assay - ...

    End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

  • Discount Price Bacterial Endotoxin Testing - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

    Discount Price Bacterial Endotoxin Testing - P...

    Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

  • Factory Outlets Endotoxin LAL Method - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

    Factory Outlets Endotoxin LAL Method - Beta-gl...

    Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

  • OEM Manufacturer BET Test Procedure - Rapid Gel Clot 10 Samples Kit – Bioendo

    OEM Manufacturer BET Test Procedure - Rapid Ge...

    Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...