Good Wholesale Vendors Bacterial Endotoxin Test Method - Endotoxin-free Glass Test Tubes – Bioendo


Product Detail

Related Video

Feedback (2)

The incredibly abundant projects administration experiences and 1 to one provider model make the superior importance of small business communication and our easy understanding of your expectations for Endotoxin Cleaning, Endotoxin Gel Clot, Gel Clot Endotoxin Test, For further queries or should you have any question regarding our products, please do not hesitate to contact us.
Good Wholesale Vendors Bacterial Endotoxin Test Method - Endotoxin-free Glass Test Tubes – Bioendo Detail:

Endotoxin-free Glass Test Tubes

 

1. Product Information

Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used for kinetic tube reader.

 

2. Product Parameter

Endotoxin level ≤0.005EU/ml

3. Product Features and Application

Made with borosilicate glass. Cover with aluminum caps. Various size suitable for gel clot reactions, sample dilutions and control standard endotoxin dilutions.

 Catalog No.  

Size mm

(outside diameter)

With

Aluminum Caps

Package

tubes/pack

T087565

Φ8×75

No

65

T107505C

Φ10×75

Yes

5

T107540

 Φ10×75

No

40

T127505C

Φ12×75

Yes

5

T127525

 Φ12×75

No

25

T1310005C

Φ13×100

Yes

5

T1310018

 Φ13×100

No

18

Why would I use endotoxin-free test consumables?

such as endotoxin free tubes; pyrogen-free tips; pyrogen-free microplates; endotoxin free sample bottles; 

According to China Pharmacopoeia, the utensils needed in the procedure of endotoxin test assay, such as sample vessel, dilution and reaction tubes, pipette tips, have to choose endotoxin free consumables. the utensils needed for the experiment need to be processed to remove possible exogenous endotoxins. If the endotoxin is not removed, it will interfere with the result of endotoxin assay.

 


Product detail pictures:

Good Wholesale Vendors Bacterial Endotoxin Test Method - Endotoxin-free Glass Test Tubes – Bioendo detail pictures

Good Wholesale Vendors Bacterial Endotoxin Test Method - Endotoxin-free Glass Test Tubes – Bioendo detail pictures

Good Wholesale Vendors Bacterial Endotoxin Test Method - Endotoxin-free Glass Test Tubes – Bioendo detail pictures


Related Product Guide:

continue to enhance, to be certain solution top quality in line with market and buyer standard requirements. Our corporation has a excellent assurance program are actually established for Good Wholesale Vendors Bacterial Endotoxin Test Method - Endotoxin-free Glass Test Tubes – Bioendo , The product will supply to all over the world, such as: Saudi Arabia, French, Azerbaijan, Our products are mainly exported to Southeast Asia, the Middle East, North America and Europe. Our quality is surely guaranteed. If you are interested in any of our products or would like to discuss a custom order, please feel free to contact us. We are looking forward to forming successful business relationships with new clients around the world in the near future.
  • Perfect services, quality products and competitive prices, we have work many times, every time is delighted, wish continue to maintain!
    5 Stars By Jenny from Gambia - 2017.10.13 10:47
    Product quality is good, quality assurance system is complete, every link can inquire and solve the problem timely!
    5 Stars By Edith from India - 2017.02.14 13:19

    Leave Your Messages

    Related products

    • OEM Customized Endotixins - Rapid Gel Clot 10 Samples Kit – Bioendo

      OEM Customized Endotixins - Rapid Gel Clot 10 ...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • 2022 Good Quality Rapid Gel Clot Test - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo

      2022 Good Quality Rapid Gel Clot Test - Gel Cl...

      Gel Clot Method Lyophilized Amebocyte Lysate Multi-test Vial G52 series 1. Product Information Gel Clot method Lyophilized Amebocyte Lysate Multi-test Vial is the Lyophilized Amebocyte Lysate reagent which select and use gel clot technique to detect endotoxin or pyrogen. As the widespread method, gel-clot test for endotoxin is simple and does not require specific and expensive instrument. Bioendo provides Gel Clot Lyophilized Amebocyte Lysate reagent in 5.2ml per vial. 2. Product Parameter...

    • Manufacturer for LAL reagent manufacturer - Eight-channel Mechanical Pipette – Bioendo

      Manufacturer for LAL reagent manufacturer - Ei...

      Eight-Channel Mechanical Pipettor 1. Product information All multi-channel mechanical pipettor have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22℃. The multichannel mechanical pipettor is idea for the detectionof bacterial endotoxin lal endotoxin testing by kinetic turbidimetric andkinetic chromogenic method. - Eight-Channel Mechanical Pipettor is available for stand...

    • China wholesale LAL gel clot - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo

      China wholesale LAL gel clot - Gel Clot Lyophi...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoules, you could add samples to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to av...

    • Fast delivery 1000ul Pipette tip - Endotoxin Assay and (1,3)-ß-D-glucan assay software – Bioendo

      Fast delivery 1000ul Pipette tip - Endotoxin A...

      Endotoxin and (1,3)-ß-D-glucan assay software 1. Product information Endotoxin and (1,3)-ß-D-glucan assay software is a powerful kinetic data analysis software,which gives the user data acquisition and processing of the maximum flexibility. Features: • Apply to Endotoxin assay,(1,3)-ß-D-glucan assay and ELISA data analysis • With standard version and clinical diagnostic version for the different user groups. • Data could be output transitions and connected to the LIS system. • Customizabl...

    • Quality Inspection for Endotoxin Kits - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Quality Inspection for Endotoxin Kits - Endoto...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...