Good Wholesale Vendors Bacterial Endotoxin Test Method - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo


Product Detail

Related Video

Feedback (2)

Together with the "Client-Oriented" enterprise philosophy, a arduous good quality control technique, sophisticated producing equipment and a sturdy R&D staff, we generally offer superior quality merchandise, superb solutions and aggressive rates for Bacterial Endotoxins, endotoxin removal, Endotoxin Indicator For Depyrogenation Usp, Sincere cooperation with you, altogether will create happy tomorrow!
Good Wholesale Vendors Bacterial Endotoxin Test Method - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo Detail:

Beta-glucans Blocker for Blocking Beta Glucan Pathway

1. Product information

There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Glucan, such as cellulose, using beta-glucans blocker would be a good idea to block the β-1,3-Glucan interference to endotoxin and LAL reagent reaction.

2. Product parameter

Endotoxin level less than 0.005EU/ml

3. Product features and application

Substitute LAL Reagent Water to reconstitute LAL reagent, blocks the beta-glucan mediates factor G pathway and insure the LAL reagent only reacts to endotoxin. For the test samples that has the (1,3)- β-D-Glucan contamination.

Catalog No.

Description

Note

Package

BH10

50mM Tris buffer, pH7.0, 10ml/vial

Used to dilute highly acidic or basic samples.

10 vials/pack

BH50

50mM Tris buffer, pH7.0, 50ml/vial

 Used to dilute highly acidic or basic samples.  10 vials/pack

BY10

10mM Magnesium Buffer, 10ml/vial

Used to overcome chelation effect.

 10 vials/pack

BT10

β-glucans blocker, 10ml/vial

Used to block β-glucan interference in Amebocyte Lysate endotoxin reactions.

 10 vials/pack

PBS50

PBS buffer endotoxin-free, 50ml/vial

Use to wash sample containers, or adjust pH

 10 vials/pack

PBS500

PBS buffer endotoxin-free, 500ml/vial

 

1 vial

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.


Product detail pictures:

Good Wholesale Vendors Bacterial Endotoxin Test Method - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

Good Wholesale Vendors Bacterial Endotoxin Test Method - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

Good Wholesale Vendors Bacterial Endotoxin Test Method - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

Good Wholesale Vendors Bacterial Endotoxin Test Method - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures


Related Product Guide:

The incredibly abundant projects administration experiences and 1 to one provider model make the superior importance of small business communication and our easy understanding of your expectations for Good Wholesale Vendors Bacterial Endotoxin Test Method - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo , The product will supply to all over the world, such as: Swiss, New York, Monaco, We've got won a good reputation among overseas and domestic clients. Adhering to the management tenet of "credit oriented, customer first, high efficiency and mature services", we warmly welcome friends from all walks of life to cooperate with us.
  • It is really lucky to meet such a good supplier, this is our most satisfied cooperation, I think we will work again!
    5 Stars By Barbara from Barbados - 2017.10.13 10:47
    This is a reputable company, they have a high level of business management, good quality product and service, every cooperation is assured and delighted!
    5 Stars By Ina from Kuwait - 2017.01.28 18:53

    Leave Your Messages

    Related products

    • Cheapest Price Bacterial Endotoxin Test Kit - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Cheapest Price Bacterial Endotoxin Test Kit - ...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • OEM China BET Testing - Rapid Gel Clot 10 Samples Kit – Bioendo

      OEM China BET Testing - Rapid Gel Clot 10 Samp...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Super Purchasing for Endotoxin Method - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Super Purchasing for Endotoxin Method - Endoto...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • High Quality endotoxin assay - Endotoxin-free Glass Test Tubes – Bioendo

      High Quality endotoxin assay - Endotoxin-free ...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • Excellent quality Depyrogenated pipette tips - Pyrogen-free Centrifuge Tube – Bioendo

      Excellent quality Depyrogenated pipette tips -...

      Pyrogen-free Centrifuge Tube   Product features: * Pyrogen-free Centrifuge tube is made from virgin polypropylene to meet the general requirements of the laboratory. * Pyrogen-free, Endotoxin level <0.005EU/ml * High strength non-toxic materials * Printed clear graduations with marking area * Gamma Radiation Sterilized * 50ml Maximum RCF is 18000g, 15ml Maximum RCF is 12000g * DNase/RNase free * Autoclavable * Temperature range is -20°C to 121°C * Leak-proof * Cap 50% longer ideal for avo...

    • 2022 Good Quality Kinetic Chromogenic Endotoxin test kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      2022 Good Quality Kinetic Chromogenic Endotoxin...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...