Good quality Micro kinetic chromogenic endotoxin test kit - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo


Product Detail

Related Video

Feedback (2)

In an effort to provide you advantage and enlarge our business enterprise, we even have inspectors in QC Staff and assure you our greatest provider and item for LAL chromogenic detection, Endotoxin Detection Methods, LAL test endotoxin, "Quality", "honesty" and "service" is our principle. Our loyalty and commitments remain respectfully at your service. Contact Us Today For further information, contact us now.
Good quality Micro kinetic chromogenic endotoxin test kit - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo Detail:

 Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay)

The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit meets the requirements of the rules of Bacterial Endotoxin Test in Pharmacopoeia. Each test requires only the 25μL sample for test and 25μL of lysate reagent. The testing principle is the same as that of the traditional kinetic chromogenic method for endotoxin detection. It has strong anti-interference ability and is very suitable for endotoxins quantitative detection in parenteral drugs, vaccines, antibodies, biological preparations and so on.

Typical users:

Pharmaceutical manufacturers, medical devices manufacturers, scientific research institutions.

Ø Less dosage of sample for test , and each test only needs 25μL of samples for testing.
Ø Adopting the pharmacopoeia-approved kinetic chromogenic method technology which can meet the requirements of GMP for data integrity and traceability.
Ø High sensitivity, up to 0.005EU/ml.
Ø Strong anti-interference ability, does not require coagulogen to form a gel, and accurately quantifies bacterial endotoxins based on the color reaction.
Ø Easy to operate, complete 96 tests at one time, and the system automatically detects and analyzes in one step.
Ø High cost-effective, higher performance.
Ø Supporting 8-well plate for micro-detection

 

Technical Parameters: 

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

MKC0505VS

Bioendo™ KC Endotoxin Test Kit (Micro Kinetic Chromogenic Assay), 90 Tests/Kit

5 Chromogenic Amebocyte Lysate, 0.5ml (18 Tests/Vial);

5 Reconstitution Buffer, 2.0ml/vial; 

0.005 to 5EU/ml

MKC0505V

0.01 to 10EU/ml

MKC0505AS

Bioendo™ KC Endotoxin Test Kit (Micro Kinetic Chromogenic Assay), 90 Tests/Kit

5 Chromogenic Amebocyte Lysate, 0.5ml (18 Tests/ampoule);

5 Reconstitution Buffer, 2.0ml/vial; 

0.005 to 5EU/ml

MKC0505A

0.01 to 10EU/ml

MPMC96

8 wells per strip

96 wells per microplate, 12pcs detachable strips.

 

What is the main feature of new Bioendo microKC kit?

Each test requires only the 25μL sample for test and 25μL of lysate reagent. Provide the professional solution that is very friendly in terms of resource utilization. 

 

Endotoxin free microplates MPMC96: the strip is individual wrap, 8 wells a strips, provide economical solution for the micro kinetic chromogenic assay.
Kinetic microplate reader Elx808 or others Elx808 series.

Pyrogen free microplate

 


Product detail pictures:

Good quality Micro kinetic chromogenic endotoxin test kit - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo detail pictures

Good quality Micro kinetic chromogenic endotoxin test kit - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo detail pictures

Good quality Micro kinetic chromogenic endotoxin test kit - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo detail pictures

Good quality Micro kinetic chromogenic endotoxin test kit - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo detail pictures


Related Product Guide:

Our company has been concentrating on brand strategy. Customers' pleasure is our greatest advertising. We also source OEM service for Good quality Micro kinetic chromogenic endotoxin test kit - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo , The product will supply to all over the world, such as: Provence, Costa rica, Azerbaijan, Our products are mainly exported to Europe, Africa, America, the Middle East and Southeast Asia and other countries and regions. We have enjoyed a great reputation among our customers for quality products and good services.We would make friends with businessmen from at home and abroad, following the purpose of "Quality First, Reputation First, the Best Services."
  • The goods we received and the sample sales staff display to us have the same quality, it is really a creditable manufacturer.
    5 Stars By Elizabeth from Karachi - 2017.03.08 14:45
    Although we are a small company, we are also respected. Reliable quality, sincere service and good credit, we are honored to be able to work with you!
    5 Stars By Diana from Haiti - 2017.06.19 13:51

    Leave Your Messages

    Related products

    • China Cheap price Chromogenic endotoxin assay - Endpoint Chromogenic Kit EC64405 – Bioendo

      China Cheap price Chromogenic endotoxin assay -...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • Low price for Pipettor tip box - Rapid Gel Clot 10 Samples Kit – Bioendo

      Low price for Pipettor tip box - Rapid Gel Clo...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Wholesale Price limulus lysate test - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo

      Wholesale Price limulus lysate test - Endotoxi...

      Endotoxin-specific Lyophilized Amebocyte Lysate 1. Product Information Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples ...

    • Chinese Professional LAL test kit price - Rapid Gel Clot 10 Samples Kit – Bioendo

      Chinese Professional LAL test kit price - Rapi...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • 2022 New Style Endotoxin Assay Kits - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      2022 New Style Endotoxin Assay Kits - Beta-glu...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • New Arrival China Dry heat tunnel validation by ECV - Rapid Gel Clot 10 Samples Kit – Bioendo

      New Arrival China Dry heat tunnel validation by...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...