With this motto in mind, we've got develop into amongst one of the most technologically innovative, cost-efficient, and price-competitive manufacturers for Bacterial Endotoxin Test Usp Chapter, Bacteria Endotoxin Test, Bacterial Endotoxin Test Method Validation Protocol, With a wide range, good quality, reasonable prices and good service, we will be your best business partner. We welcome new and old customers from all walks of life to contact us for future business relationships and achieving mutual success!
Good Quality Gel Clot Assay - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo Detail:

Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial

1. Product Information

Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in Vial, you could add sample to the vial directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many vials use each time to avoid waste. Endotoxin free tube for dilution of CSE is necessary. Operation of endotoxin detection by choice of Bioendo Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial conforms to the USP, the EP.

2. Product Parameter

Gel clot assay single test glass vial

Sensitivities:  0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25 EU/ml

3.Product Feature and Application

Single step endotoxin detection,

without expensive endotoxin assay instruments,

Suitable for end-product endotoxin testing before product released,

Product sensitivity standardized according to US Pharmacopoeia criterion and China Pharmacopoeia criterion.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from lysate of amebocytes (white blood cells) from the horseshoe crab.

Catalog number Sensitivity (EU/ml) (IU/ml) Tests/Vial Vials/Pack
G020015 0.015 1 50
G020030 0.03 1 50
G020060 0.06 1 50
G020125 0.125 1 50
G020250 0.25 1 50
G020500 0.5 1 50

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

Why the most selected gel clot assay kit G02:

1. The most economical and commonly used test reagent for endotoxin detection.

2. Single test in a vial for one stepping reduce the risk of contamination.

3. Gel clot assay single test glass vial no need sophisticated microplate reader.

4. Saving endotoxin free tube when using G02 series to test endotoxins in the procedure of endotoxin test assay’s operation.

Related products in the endotoxin test assay:
Water for Bacterial Endotoxins Test (BET),  Recommend TRW50 or TRW100
Endotoxin free glass tube ( dilution tube ),  Recommend T1310018
Pyrogen free tips,  Recommend PT25096 or PT100096
Pipettor, Recommend PSB0220
Test Tube Rack,
Incubation Instrument (Water Bath or Dry Heat Incubator ), Recommend Dry Heat Incubator TAL-M2
Vortex Mixter, Recommend VXH.
Control Standard Endotoxin, CSE10V.

Product detail pictures:

Good Quality Gel Clot Assay - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures

Good Quality Gel Clot Assay - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures

Good Quality Gel Clot Assay - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures

Good Quality Gel Clot Assay - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures

Good Quality Gel Clot Assay - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures

Good Quality Gel Clot Assay - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures


Related Product Guide:

In an effort to provide you advantage and enlarge our business enterprise, we even have inspectors in QC Staff and assure you our greatest provider and item for Good Quality Gel Clot Assay - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo , The product will supply to all over the world, such as: Puerto Rico, Borussia Dortmund, Plymouth, We've a skilled sales team, they have mastered the best technology and manufacturing processes, have years of experience in foreign trade sales, with customers able to communicate seamlessly and accurately understand the real needs of customers, providing customers with personalized service and unique merchandise.
  • The factory has advanced equipment, experienced staffs and good management level, so product quality had assurance, this cooperation is very relaxed and happy!
    5 Stars By Cindy from Qatar - 2017.09.16 13:44
    Timely delivery, strict implementation of the contract provisions of the goods, encountered special circumstances, but also actively cooperate, a trustworthy company!
    5 Stars By Rae from Amsterdam - 2018.02.12 14:52

    Leave Your Messages

    Related products

    • Chinese Professional LAL test kit price - Rapid Gel Clot single test kit – Bioendo

      Chinese Professional LAL test kit price - Rapi...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • PriceList for Pyrogen Free Tube - Eight-channel Mechanical Pipette – Bioendo

      PriceList for Pyrogen Free Tube - Eight-channe...

      Eight-Channel Mechanical Pipettor 1. Product information All multi-channel mechanical pipettor have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22℃. The multichannel mechanical pipettor is idea for the detectionof bacterial endotoxin lal endotoxin testing by kinetic turbidimetric andkinetic chromogenic method. - Eight-Channel Mechanical Pipettor is available for stand...

    • High Quality LAL test gel clot - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo

      High Quality LAL test gel clot - Gel Clot Lyop...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoule, you could add sample to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to avoi...

    • Factory made hot-sale Bacterial Endotoxin Test Validation - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Factory made hot-sale Bacterial Endotoxin Test ...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • Chinese wholesale Rapid Gel Clot Assay - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo

      Chinese wholesale Rapid Gel Clot Assay - Gel C...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoule, you could add sample to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to avoi...

    • Online Exporter Endotoxin Detection System - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Online Exporter Endotoxin Detection System - P...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...