Good Quality Gel Clot Assay - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo


Product Detail

Related Video

Feedback (2)

We know that we only thrive if we can guarantee our combined rate competiveness and good quality advantageous at the same time for Endotoxin Of Bacteria, Endotoxin Detection Kit, BET Endotoxin Test, Base on the business concept of Quality first, we would like to meet more and more friends in the word and we hope provide the best product and service to you.
Good Quality Gel Clot Assay - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo Detail:

Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule

1. Product Information

Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoule, you could add sample to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to avoid waste. Endotoxin free tubes for the dilution of Lyophilized CSE is necessary. Operation of endotoxin detection use Bioendo Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule conforms to the national Pharmacopoeia.  

2. Product Parameter

Gel clot assay single test glass ampoule.

Sensitivities:  0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25 EU/ml, 0.5EU/ml. 

3.Product Feature and Application

Single step endotoxin detection,

Normal water bath or dry heat incubator is available for the gel clot method. 

Suitable for end-product endotoxin testing before product released.

Product sensitivity standardized according to the China Pharmacopoeia criterion.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from lysate of amebocytes (white blood cells) from the horseshoe crab.

Catalog No.

Sensitivity EU/ml

Description

Kit Contents

GS010030

0.03

Bioendo Gel Clot Endotoxin Test Kit, Single Test in Ampoule.

10 tests per pack

GS010060

0.06

GS010125

0.125

GS010250

0.25

GS010500

0.5

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

Why the most selected gel clot assay kit G01:

1. The most economical and commonly used test reagent for endotoxin detection.

2. Single test in a ampoule for one step reduce the risk of contamination.

3. Gel clot assay single test glass ampoule no need sophisticated microplate reader.

4. Saving endotoxin free tube when using G01 series to test endotoxins in the procedure of endotoxin test assay’s operation.

Related products in the endotoxin test assay:
Water for Bacterial Endotoxins Test (BET),  Recommend TRW02, TRW50 or TRW100
Endotoxin free glass tube ( dilution tube ),  Recommend T1310018
Pyrogen free tips,  Recommend PT25096 or PT100096
Pipettor, Recommend PSB0220
Test Tube Rack,
Incubation Instrument (Water Bath or Dry Heat Incubator ), Recommend Dry Heat Incubator TAL-M2
Vortex Mixter, Recommend VXH.
Control Standard Endotoxin, CSE10A.

Product detail pictures:

Good Quality Gel Clot Assay - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo detail pictures

Good Quality Gel Clot Assay - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo detail pictures

Good Quality Gel Clot Assay - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo detail pictures


Related Product Guide:

It is actually our accountability to satisfy your needs and effectively serve you. Your pleasure is our best reward. We're on the lookout forward for your stop by for joint growth for Good Quality Gel Clot Assay - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo , The product will supply to all over the world, such as: Lebanon, Slovakia, Angola, Our company, is always regarding quality as company' s foundation, seeking for development via high degree of credibility , abiding by iso9000 quality management standard strictly , creating top-ranking company by spirit of progress-marking honesty and optimism.
  • The goods are very perfect and the company sales manager is warmful, we will come to this company to purchase next time.
    5 Stars By Esther from South Korea - 2018.09.23 17:37
    We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
    5 Stars By Jessie from Brunei - 2017.10.25 15:53

    Leave Your Messages

    Related products

    • Hot sale Kinetic Turbidimetric TAL Assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      Hot sale Kinetic Turbidimetric TAL Assay - Bio...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • Wholesale Price China Kinetic Turbidimetric LAL kit for endotoxin detection - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      Wholesale Price China Kinetic Turbidimetric LAL...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • Top Quality Endotoxin - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo

      Top Quality Endotoxin - LAL Reagent Water (Wat...

      LAL Reagent Water ( Water for Bacterial Endotoxins Test / Water for BET / TAL Reagnt Water )  1. Product Information LAL Reagent Water (Water for Bacterial Endotoxins Test or BET Water or Water for BET )is specially processed super-purified endotoxin free water is used for Endotoxin test. Its endotoxin concentration is less than 0.005 EU/ml. Various packages, such as 2ml, 10ml, 50ml, 100ml and 500ml per unit, are provided for users’ convenience. LAL Reagent Water (Water for BET) could...

    • Good User Reputation for Bacterial Endotoxins Testing - Endotoxin-free Glass Test Tubes – Bioendo

      Good User Reputation for Bacterial Endotoxins T...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • High definition Control Standard Endotoxin Preparation - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      High definition Control Standard Endotoxin Prep...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • China wholesale LAL gel clot - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo

      China wholesale LAL gel clot - Gel Clot Lyophi...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoule, you could add sample to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to avoi...