Factory Supply Pipette tip box - Rapid Gel Clot single test kit – Bioendo


Product Detail

Related Video

Feedback (2)

All we do is usually connected with our tenet " Consumer initial, Rely on 1st, devoting around the food stuff packaging and environmental safety for LAL Reagent, Endotoxin Method, Kinetic Turbidimetric Endotoxin test Kit, We warmly welcome you to build cooperation and generate a brilliant long term together with us.
Factory Supply Pipette tip box - Rapid Gel Clot single test kit – Bioendo Detail:

Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit)

1. Product Information

Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes.
Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures in the operation of rapid endotoxin assay, the whole operation not required sophisticated experimental equipment, incubation by a dry heat incubator. It is especial suitable for the endotoxins analysis in the water or dialysate.

20190819091605_48802

2. Product Parameter

Sensitivity Range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5EU/ml

One sample test in a kit. 

Assay time: less than 30 minutes. 

Catalog No.

Description

Kit Contents

Sensitivity

EU/ml

Reaction Time

minutes

RG025003

BioendoTM Rapid Gel Clot Endotoxin Assay Kit, One Sample Kit

1 SPL Tube;

1 PPC Tube;

1 Endotoxin-free Sample Bottle;

3 Pyrogen-free Pipettors;

0.03

≤60

RG025006

0.06

≤60

RG0250125

0.125

≤45

RG025025

0.25

≤30

RG025050

0.5

≤30

 

3. Kit Application

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit provide a kind of rapid endotoxin testing solution, the featured application in the field of dialysis. 

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab. In the operation procedure,  the dilution of control standard endotoxin is simple and convenient. Endotoxin free sample container and pyrogen free transfer pipette is required, Sophisticated instrument is not required, recommend Bioendo Dry heat incubator TAL-MT use in the procedure of incubation. 

Kit Configuration:

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit contains: 

1 piece of SPL Tube, 1 piece of PPC Tube, 1 piece of Endotoxin-free Sample Bottle. (endotoxin free top level), 

1 Pack of Transfer Pipette 3 pieces. (endotoxin free top level)


Product detail pictures:

Factory Supply Pipette tip box - Rapid Gel Clot single test kit – Bioendo detail pictures

Factory Supply Pipette tip box - Rapid Gel Clot single test kit – Bioendo detail pictures

Factory Supply Pipette tip box - Rapid Gel Clot single test kit – Bioendo detail pictures

Factory Supply Pipette tip box - Rapid Gel Clot single test kit – Bioendo detail pictures

Factory Supply Pipette tip box - Rapid Gel Clot single test kit – Bioendo detail pictures


Related Product Guide:

Our workforce through professional training. Skilled professional knowledge, solid sense of service, to fulfill the services demands of consumers for Factory Supply Pipette tip box - Rapid Gel Clot single test kit – Bioendo , The product will supply to all over the world, such as: Serbia, Slovakia, South Korea, Now, with the development of internet, and the trend of internationalization, we have decided to extend business to overseas market. With the propose of bringing more profits to oversea customers by providing directly abroad. So we have changed our mind, from home to abroad, hope to give our customers more profit, and looking forward to more chance to make business.
  • As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.
    5 Stars By Elaine from Finland - 2018.06.18 19:26
    This is a honest and trustworthy company, technology and equipment are very advanced and the prodduct is very adequate, there is no worry in the suppliment.
    5 Stars By Joyce from Pakistan - 2018.02.12 14:52

    Leave Your Messages

    Related products

    • Reasonable price Depyrogenated tips - Pyrogen-free Centrifuge Tube – Bioendo

      Reasonable price Depyrogenated tips - Pyrogen-...

      Pyrogen-free Centrifuge Tube   Product features: * Pyrogen-free Centrifuge tube is made from virgin polypropylene to meet the general requirements of the laboratory. * Pyrogen-free, Endotoxin level <0.005EU/ml * High strength non-toxic materials * Printed clear graduations with marking area * Gamma Radiation Sterilized * 50ml Maximum RCF is 18000g, 15ml Maximum RCF is 12000g * DNase/RNase free * Autoclavable * Temperature range is -20°C to 121°C * Leak-proof * Cap 50% longer ideal for avo...

    • Factory made hot-sale Bacterial Endotoxin Test Validation - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo

      Factory made hot-sale Bacterial Endotoxin Test ...

      LAL Reagent Water ( Water for Bacterial Endotoxins Test / Water for BET / TAL Reagnt Water )  1. Product Information LAL Reagent Water (Water for Bacterial Endotoxins Test or BET Water or Water for BET )is specially processed super-purified endotoxin free water is used for Endotoxin test. Its endotoxin concentration is less than 0.005 EU/ml. Various packages, such as 2ml, 10ml, 50ml, 100ml and 500ml per unit, are provided for users’ convenience. LAL Reagent Water (Water for BET) could...

    • Hot New Products Kinetic chromogenic TAL test kit - Endpoint Chromogenic Kit EC64405 – Bioendo

      Hot New Products Kinetic chromogenic TAL test k...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • Wholesale Price Micro kinetic chromogenic endotoxin assay - Endpoint Chromogenic Kit EC80545 – Bioendo

      Wholesale Price Micro kinetic chromogenic endot...

      Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) 1. Product Information Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum abso...

    • Special Design for Bacterial Endotoxin Test Methods - Endotoxin-free Glass Test Tubes – Bioendo

      Special Design for Bacterial Endotoxin Test Met...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • 2022 wholesale price Chromogenic LAL test - Endpoint Chromogenic Kit EC64405 – Bioendo

      2022 wholesale price Chromogenic LAL test - En...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...