Our organization insists all along the quality policy of "product quality is base of business survival; purchaser gratification is the staring point and ending of an business; persistent improvement is eternal pursuit of staff" as well as the consistent purpose of "reputation 1st, purchaser first" for LAL testing medical device, TAL gel clot, Bacterial Endotoxins Testing, We, with fantastic passion and faithfulness, are willing to offer you with best services and striding forward with you to make a bright foreseeable future.
Factory Cheap Hot limulus amebocyte - Rapid Gel Clot 10 Samples Kit – Bioendo Detail:

Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit)
1. Product Information

Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedures are very convenient, additional experimental equipment are required. It is a convenient and rapid way to detect endotoxin in especial suitable for water or dialysate.

20190819091605_48802

2. Product Parameter

Sensitivity Range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5EU/ml

10 sample tests in the kit. 

Assay time: less than 30 minutes

3. Product Application

Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate as well as do quickly endotoxin detection in life science research.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Description

Kit Contents

Sensitivity

EU/ml

Reaction Time

minutes

RG10025003

BioendoTM Rapid Gel Clot Endotoxin Assay Kit, 10 Samples Kit

10 SPL Tubes;

10 PPC Tubes;

10 Endotoxin-free Sample Bottles;

10 Packs of (3pcs Transfer Pipettes)

0.03

≤60

RG10025006

0.06

≤60

RG100250125

0.125

≤45

RG10025025

0.25

≤30

RG10025050

0.5

≤30

Kit configuration: 
Bioendo Rapid Gel Clot Endotoxin Assay Kit contains: 
10 SPL Tube, 10 PPC Tube, 10 Endotoxin-free Sample Bottle, 10 Pack of Transfer Pipette 3 pieces.
Simple and convenient procedure in the dilution of control standard endotoxin. Endotoxin free sample container and pyrogen free transfer pipette is required, Sophisticated instruments are required, recommend Bioendo Dry heat incubator TAL-MT use in the procedure of incubation.   

Product detail pictures:

Factory Cheap Hot limulus amebocyte - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures

Factory Cheap Hot limulus amebocyte - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures

Factory Cheap Hot limulus amebocyte - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures

Factory Cheap Hot limulus amebocyte - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures


Related Product Guide:

To be a result of ours specialty and repair consciousness, our corporation has won a good popularity amid consumers everywhere in the environment for Factory Cheap Hot limulus amebocyte - Rapid Gel Clot 10 Samples Kit – Bioendo , The product will supply to all over the world, such as: venezuela, Uruguay, Florida, With well educated, innovative and energetic staff, we are responsible for all elements of research, design, manufacture, sale and distribution. By studying and developing new techniques, we are not only following but also leading fashion industry. We listen attentively to the feedback from our customers and provide instant replies. You will instantly feel our professional and attentive service.
  • The quality of the products is very good, especially in the details, can be seen that the company work actively to satisfy customer's interest, a nice supplier.
    5 Stars By Maggie from Paris - 2018.12.30 10:21
    It's really lucky to find such a professional and responsible manufacturer, the product quality is good and delivery is timely, very nice.
    5 Stars By Elsie from Kenya - 2018.09.29 13:24

    Leave Your Messages

    Related products

    • OEM/ODM China Kinetic chromogenic TAL test kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      OEM/ODM China Kinetic chromogenic TAL test kit ...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...

    • PriceList for endotoxin challenge test - Pyrogen-free Pipette tips and Consumables – Bioendo

      PriceList for endotoxin challenge test - Pyrog...

      Pyrogen-free Pipette tips and tip box 1. Product information We offer various low endotoxin, pyrogen-free accessories,includes Water for Bacterial Endotoxins Test, endotoxin-free test tubes, pyrogen-free pipette tips, pyroegn-free microplates for your operation. High quality depyrogenated and low endotoxin level consumables to ensure the success of your endotoxin assays. Pyrogen-free pipette tips are certified to contain <0.001 EU/ml endotoxin. The tips allow more flexibility with diffe...

    • Good quality Control Standard Endotoxin COA - Control Standard Endotoxin (CSE) – Bioendo

      Good quality Control Standard Endotoxin COA - ...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • Factory Cheap Hot Kinetic Turbidimetric Endotoxin test Kit - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      Factory Cheap Hot Kinetic Turbidimetric Endotox...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...

    • OEM/ODM China Kinetic chromogenic TAL test kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      OEM/ODM China Kinetic chromogenic TAL test kit ...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...

    • Good User Reputation for Bacterial Endotoxins Testing - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Good User Reputation for Bacterial Endotoxins T...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...