We goal to understand excellent disfigurement from the manufacturing and supply the top support to domestic and abroad clients wholeheartedly for Control Standard Endotoxin Dilution, Kinetic chromogenic TAL test, Endotoxin Determination, We adhere on the tenet of "Services of Standardization, to meet Customers' Demands".
Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo Detail:

Fungi(1,3)-β-D-glucan Assay Kit

Product information:

(1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) measures levels of (1-3)-β-D-Glucan by kinetic chromogenic method. The assay is based upon a modification factor G pathway of the Amebocyte Lysate (AL). (1-3)-β-D-Glucan activates Factor G, the activated Factor G converts the inactive proclotting enzyme to the active clotting enzyme, which in turn cleaves pNA from the chromogenic peptide substrate. pNA is a chromophore that absorbs at 405 nm. The rate of OD increase at 405nm of the reaction solution is directly proportional to the concentration of the reaction solution (1-3)-β-D-Glucan. The concentration of (1-3)-β-D-Glucan in the reaction solution can be calculated according to the standard curve by recording the rate of change of the OD value of the reaction solution through optical detection equipment and software.

The highly sensitive, rapid assay assists clinicians in identifying Invasive Fungal Disease (IFD) early in the disease process. The kit has obtained EU CE qualification and can be used for clinical diagnosis.

 

Immunosuppressed patients are at high risk for developing invasive fungal disease, which is often difficult to diagnose. Affected patient populations include:

Cancer patients undergoing chemotherapy

Stem Cell and Organ Transplant patients

Burn patients

HIV patients

ICU patients

 

Product parameter:

Assay range: 25-1000 pg/ml

Assay time: 40 minutes, sample pre-treatment: 10 minutes

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

 

Catalog number:

 

KCG50 (50 tests / kit):  Chromogenic Amebocyte Lysate  1.1mL×5

                   (1-3)-β-D-Glucan standard       1mL×2

                   Reconstitution Buffer         10mL×2

                   Tris Buffer                  6mL×1

                   Sample Treatment Solution A   3mL×1

                   Sample Treatment Solution B   3mL×1

 

KCG80 (80 tests / kit):  Chromogenic Amebocyte Lysate  1.7mL×5

                   (1-3)-β-D-Glucan standard       1mL×2

                   Reconstitution Buffer         10mL×2

                   Tris Buffer                  6mL×1

                   Sample Treatment Solution A   3mL×1

                   Sample Treatment Solution B   3mL×1

 

KCG100 (100 tests / kit): Chromogenic Amebocyte Lysate  2.2mL×5

                   (1-3)-β-D-Glucan standard       1mL×2

                   Reconstitution Buffer         10mL×2

                   Tris Buffer                  6mL×1

                   Sample Treatment Solution A   3mL×1

                   Sample Treatment Solution B   3mL×1

 

Product Condition:

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

 


Product detail pictures:

Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo detail pictures

Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo detail pictures


Related Product Guide:

We're going to dedicate ourselves to offering our esteemed shoppers with the most enthusiastically considerate solutions for Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo , The product will supply to all over the world, such as: Kenya, California, Canberra, They are sturdy modeling and promoting effectively all over the world. Never ever disappearing major functions within a quick time, it's a have to in your case of fantastic good quality. Guided by the principle of Prudence, Efficiency, Union and Innovation. the corporation. ake an excellent efforts to expand its international trade, raise its organization. rofit and raise its export scale. We've been confident that we've been going to have a bright prospect and to be distributed all over the world in the years to come.
  • This is a very professional and honest Chinese supplier, from now on we fell in love with the Chinese manufacturing.
    5 Stars By Martina from Stuttgart - 2017.11.20 15:58
    Hope that the company could stick to the enterprise spirit of "Quality, Efficiency, Innovation and Integrity", it will be better and better in the future.
    5 Stars By Betsy from Adelaide - 2018.06.05 13:10

    Leave Your Messages

    Related products

    • Manufacturer of Dry Heat Sterilization Validation – Pyrogen-free Centrifuge Tube – Bioendo

      Manufacturer of Dry Heat Sterilization Validati...

      Pyrogen-free Centrifuge Tube   Product features: * Pyrogen-free Centrifuge tube is made from virgin polypropylene to meet the general requirements of the laboratory. * Pyrogen-free, Endotoxin level <0.005EU/ml * High strength non-toxic materials * Printed clear graduations with marking area * Gamma Radiation Sterilized * 50ml Maximum RCF is 18000g, 15ml Maximum RCF is 12000g * DNase/RNase free * Autoclavable * Temperature range is -20°C to 121°C * Leak-proof * Cap 50% longer ideal for avo...

    • Hot-selling Kinetic chromogenic LAL test kit - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo

      Hot-selling Kinetic chromogenic LAL test kit -...

       Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay) The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit mee...

    • Hot sale Kinetic Turbidimetric TAL Assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      Hot sale Kinetic Turbidimetric TAL Assay - Bio...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • OEM/ODM China Kinetic Chromogenic Endotoxin Assay Kit - Endpoint Chromogenic Kit EC64405 – Bioendo

      OEM/ODM China Kinetic Chromogenic Endotoxin Ass...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • Best quality Endotoxin Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo

      Best quality Endotoxin Gel Clot Method - Gel C...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoule, you could add sample to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to avoi...

    • Hot-selling Pipette tip supplier - Compact Modular Dry Heat Incubator – Bioendo

      Hot-selling Pipette tip supplier - Compact Mod...

      Dry Heat Incubator 1. Product description: Dry Heat Incubator TAL-M2 is amicroprocessor-controlled device, high precision of temperature control, samplepreparation parallelism, as an alternative to the traditional water bathdevice. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules. TAL- M2 A Dry bath incubat...