Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo


Product Detail

Related Video

Feedback (2)

Our advantages are reduced prices,dynamic product sales workforce,specialized QC,solid factories,superior quality services for Endotoxin Method, Endosafe LAL Kit, LAL gel clot assey, We believe that our warm and professional service will bring you pleasant surprises as well as fortune.
Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo Detail:

Fungi(1,3)-β-D-glucan Assay Kit

Product information:

(1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) measures levels of (1-3)-β-D-Glucan by kinetic chromogenic method. The assay is based upon a modification factor G pathway of the Amebocyte Lysate (AL). (1-3)-β-D-Glucan activates Factor G, the activated Factor G converts the inactive proclotting enzyme to the active clotting enzyme, which in turn cleaves pNA from the chromogenic peptide substrate. pNA is a chromophore that absorbs at 405 nm. The rate of OD increase at 405nm of the reaction solution is directly proportional to the concentration of the reaction solution (1-3)-β-D-Glucan. The concentration of (1-3)-β-D-Glucan in the reaction solution can be calculated according to the standard curve by recording the rate of change of the OD value of the reaction solution through optical detection equipment and software.

The highly sensitive, rapid assay assists clinicians in identifying Invasive Fungal Disease (IFD) early in the disease process. The kit has obtained EU CE qualification and can be used for clinical diagnosis.

 

Immunosuppressed patients are at high risk for developing invasive fungal disease, which is often difficult to diagnose. Affected patient populations include:

Cancer patients undergoing chemotherapy

Stem Cell and Organ Transplant patients

Burn patients

HIV patients

ICU patients

 

Product parameter:

Assay range: 25-1000 pg/ml

Assay time: 40 minutes, sample pre-treatment: 10 minutes

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

 

Catalog number:

 

KCG50 (50 tests / kit):  Chromogenic Amebocyte Lysate  1.1mL×5

                   (1-3)-β-D-Glucan standard       1mL×2

                   Reconstitution Buffer         10mL×2

                   Tris Buffer                  6mL×1

                   Sample Treatment Solution A   3mL×1

                   Sample Treatment Solution B   3mL×1

 

KCG80 (80 tests / kit):  Chromogenic Amebocyte Lysate  1.7mL×5

                   (1-3)-β-D-Glucan standard       1mL×2

                   Reconstitution Buffer         10mL×2

                   Tris Buffer                  6mL×1

                   Sample Treatment Solution A   3mL×1

                   Sample Treatment Solution B   3mL×1

 

KCG100 (100 tests / kit): Chromogenic Amebocyte Lysate  2.2mL×5

                   (1-3)-β-D-Glucan standard       1mL×2

                   Reconstitution Buffer         10mL×2

                   Tris Buffer                  6mL×1

                   Sample Treatment Solution A   3mL×1

                   Sample Treatment Solution B   3mL×1

 

Product Condition:

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

 


Product detail pictures:

Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo detail pictures

Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo detail pictures


Related Product Guide:

We insist on offering premium quality manufacturing with superior business concept, honest product sales as well as finest and fast assistance. it will bring you not only the good quality product or service and huge profit, but the most significant is to occupy the endless market for Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo , The product will supply to all over the world, such as: Buenos Aires, Swaziland, Madrid, We guarantee that our company will try our best to reduce customer purchase cost , shorten the period of purchase , stable merchandise quality , increase customers' satisfaction and achieve win-win situation .
  • It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
    5 Stars By Amber from Denver - 2018.02.12 14:52
    This supplier offers high quality but low price products, it is really a nice manufacturer and business partner.
    5 Stars By Gail from venezuela - 2017.10.23 10:29

    Leave Your Messages

    Related products

    • 2022 Latest Design Bioburden And Endotoxin Testing - Endotoxin-free Glass Test Tubes – Bioendo

      2022 Latest Design Bioburden And Endotoxin Test...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • OEM/ODM Factory Application Of LAL Test - Eight-channel Mechanical Pipette – Bioendo

      OEM/ODM Factory Application Of LAL Test - Eigh...

      Eight-Channel Mechanical Pipettor 1. Product information All multi-channel mechanical pipettor have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22℃. The multichannel mechanical pipettor is idea for the detectionof bacterial endotoxin lal endotoxin testing by kinetic turbidimetric andkinetic chromogenic method. - Eight-Channel Mechanical Pipettor is available for stand...

    • Low price for Pipettor tip box - Single-Channel Mechanical Pipettes (Semi-sterile) – Bioendo

      Low price for Pipettor tip box - Single-Channe...

      Single-Channel Mechanical Pipettes (Semi-sterile)   1. Product Information The Single-Channel Mechanical Pipettes (Semi-sterile) is adjustable, which could be used to dispense liquid precisely. Measuring volume of our Single-Channel Mechanical Pipettes (Semi-sterile) ranges from 0.1μL to 5mL. Products are produced based on ISO8655/DIN12650. It could be widely employed on endotoxin detection, etc..   2. Product Features - Light weight, economic - The pipettes cover volume range from 0.1μL to 5...

    • Professional China bacterial endotoxin test - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo

      Professional China bacterial endotoxin test - ...

      LAL Reagent Water ( Water for Bacterial Endotoxins Test / Water for BET / TAL Reagnt Water )  1. Product Information LAL Reagent Water (Water for Bacterial Endotoxins Test or BET Water or Water for BET )is specially processed super-purified endotoxin free water is used for Endotoxin test. Its endotoxin concentration is less than 0.005 EU/ml. Various packages, such as 2ml, 10ml, 50ml, 100ml and 500ml per unit, are provided for users’ convenience. LAL Reagent Water (Water for BET) could...

    • Best quality limulus lysate assay - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo

      Best quality limulus lysate assay - Endotoxin-...

      Endotoxin-specific Lyophilized Amebocyte Lysate 1. Product Information Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples ...

    • Hot sale Pyrogen free tip box - Single-Channel Mechanical Pipettor – Bioendo

      Hot sale Pyrogen free tip box - Single-Channel...

      Single-Channel Mechanical Pipettor   1. Product Information Single channel mechanical pipette is ideal tool to support endotoxin detection with Lyophilized Amebocyte Lysate which covers gel-clot technique, kinetic turbidimetric technique, kinetic chromogenic technique, and end-point chromogenic technique. All pipettors are produced by following ISO8655 – 2:2002. The quality control involves gravimetric testing of each pipette with distilled water at 22℃.   2. Product Features: - ...