Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo


Product Detail

Related Video

Feedback (2)

Our commission should be to provide our customers and consumers with ideal top quality and aggressive portable digital products for Endotoxin Detection Kit Sigma, Endotoxin Free Tubes, BET Test Procedure, Please sense no cost to speak to us anytime. We are going to reply you when we receive your inquiries. Remember to note that samples are available before we start our business enterprise.
Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo Detail:

Fungi(1,3)-β-D-glucan Assay Kit

Product information:

(1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) measures levels of (1-3)-β-D-Glucan by kinetic chromogenic method. The assay is based upon a modification factor G pathway of the Amebocyte Lysate (AL). (1-3)-β-D-Glucan activates Factor G, the activated Factor G converts the inactive proclotting enzyme to the active clotting enzyme, which in turn cleaves pNA from the chromogenic peptide substrate. pNA is a chromophore that absorbs at 405 nm. The rate of OD increase at 405nm of the reaction solution is directly proportional to the concentration of the reaction solution (1-3)-β-D-Glucan. The concentration of (1-3)-β-D-Glucan in the reaction solution can be calculated according to the standard curve by recording the rate of change of the OD value of the reaction solution through optical detection equipment and software.

The highly sensitive, rapid assay assists clinicians in identifying Invasive Fungal Disease (IFD) early in the disease process. The kit has obtained EU CE qualification and can be used for clinical diagnosis.

 

Immunosuppressed patients are at high risk for developing invasive fungal disease, which is often difficult to diagnose. Affected patient populations include:

Cancer patients undergoing chemotherapy

Stem Cell and Organ Transplant patients

Burn patients

HIV patients

ICU patients

 

Product parameter:

Assay range: 25-1000 pg/ml

Assay time: 40 minutes, sample pre-treatment: 10 minutes

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

 

Catalog number:

 

KCG50 (50 tests / kit):  Chromogenic Amebocyte Lysate  1.1mL×5

                   (1-3)-β-D-Glucan standard       1mL×2

                   Reconstitution Buffer         10mL×2

                   Tris Buffer                  6mL×1

                   Sample Treatment Solution A   3mL×1

                   Sample Treatment Solution B   3mL×1

 

KCG80 (80 tests / kit):  Chromogenic Amebocyte Lysate  1.7mL×5

                   (1-3)-β-D-Glucan standard       1mL×2

                   Reconstitution Buffer         10mL×2

                   Tris Buffer                  6mL×1

                   Sample Treatment Solution A   3mL×1

                   Sample Treatment Solution B   3mL×1

 

KCG100 (100 tests / kit): Chromogenic Amebocyte Lysate  2.2mL×5

                   (1-3)-β-D-Glucan standard       1mL×2

                   Reconstitution Buffer         10mL×2

                   Tris Buffer                  6mL×1

                   Sample Treatment Solution A   3mL×1

                   Sample Treatment Solution B   3mL×1

 

Product Condition:

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

 


Product detail pictures:

Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo detail pictures

Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo detail pictures


Related Product Guide:

Our enterprise since its inception, often regards solution excellent as enterprise life, continually strengthen output technology, enhance product high quality and continually strengthen organization total high-quality administration, in strict accordance using the national standard ISO 9001:2000 for Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo , The product will supply to all over the world, such as: Latvia, Vietnam, Iran, Our company has abundant strength and possesses a steady and perfect sales network system. We wish we could establish sound business relationships with all customers from at home and abroad on the basis of mutual benefits.
  • This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!
    5 Stars By Ann from Cologne - 2017.08.18 11:04
    This is a very professional and honest Chinese supplier, from now on we fell in love with the Chinese manufacturing.
    5 Stars By Rigoberto Boler from Toronto - 2018.09.08 17:09

    Leave Your Messages

    Related products

    • Big Discount 85 Bacterial Endotoxins Test - Endotoxin-free Glass Test Tubes – Bioendo

      Big Discount 85 Bacterial Endotoxins Test - En...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • Bottom price 250ul Pipette tip box - Rapid Gel Clot single test kit – Bioendo

      Bottom price 250ul Pipette tip box - Rapid Gel...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • Hot Selling for Bacterial Endotoxin Test As Per Indian Pharmacopoeia - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Hot Selling for Bacterial Endotoxin Test As Per...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • Wholesale Discount BET Endotoxin Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Wholesale Discount BET Endotoxin Test - Beta-g...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Manufacturer for LAL reagent manufacturer - Single-Channel Mechanical Pipettes (Semi-sterile) – Bioendo

      Manufacturer for LAL reagent manufacturer - Si...

      Single-Channel Mechanical Pipettes (Semi-sterile)   1. Product Information The Single-Channel Mechanical Pipettes (Semi-sterile) is adjustable, which could be used to dispense liquid precisely. Measuring volume of our Single-Channel Mechanical Pipettes (Semi-sterile) ranges from 0.1μL to 5mL. Products are produced based on ISO8655/DIN12650. It could be widely employed on endotoxin detection, etc..   2. Product Features - Light weight, economic - The pipettes cover volume range from 0.1μL to 5...

    • Factory made hot-sale Bacterial Endotoxin Test Validation - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo

      Factory made hot-sale Bacterial Endotoxin Test ...

      LAL Reagent Water ( Water for Bacterial Endotoxins Test / Water for BET / TAL Reagnt Water )  1. Product Information LAL Reagent Water (Water for Bacterial Endotoxins Test or BET Water or Water for BET )is specially processed super-purified endotoxin free water is used for Endotoxin test. Its endotoxin concentration is less than 0.005 EU/ml. Various packages, such as 2ml, 10ml, 50ml, 100ml and 500ml per unit, are provided for users’ convenience. LAL Reagent Water (Water for BET) could...