Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo


Product Detail

Related Video

Feedback (2)

As for aggressive costs, we believe that you will be searching far and wide for anything that can beat us. We can state with absolute certainty that for such high-quality at such rates we have been the lowest around for Bacterial Endotoxin Calculation, Bacterial Endotoxin Test Kit, Endotoxin Free Tube, We welcome new and old customers from all walks of life to contact us for future business relationships and achieving mutual success!
Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo Detail:

Fungi(1,3)-β-D-glucan Assay Kit

Product information:

(1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) measures levels of (1-3)-β-D-Glucan by kinetic chromogenic method. The assay is based upon a modification factor G pathway of the Amebocyte Lysate (AL). (1-3)-β-D-Glucan activates Factor G, the activated Factor G converts the inactive proclotting enzyme to the active clotting enzyme, which in turn cleaves pNA from the chromogenic peptide substrate. pNA is a chromophore that absorbs at 405 nm. The rate of OD increase at 405nm of the reaction solution is directly proportional to the concentration of the reaction solution (1-3)-β-D-Glucan. The concentration of (1-3)-β-D-Glucan in the reaction solution can be calculated according to the standard curve by recording the rate of change of the OD value of the reaction solution through optical detection equipment and software.

The highly sensitive, rapid assay assists clinicians in identifying Invasive Fungal Disease (IFD) early in the disease process. The kit has obtained EU CE qualification and can be used for clinical diagnosis.

 

Immunosuppressed patients are at high risk for developing invasive fungal disease, which is often difficult to diagnose. Affected patient populations include:

Cancer patients undergoing chemotherapy

Stem Cell and Organ Transplant patients

Burn patients

HIV patients

ICU patients

 

Product parameter:

Assay range: 25-1000 pg/ml

Assay time: 40 minutes, sample pre-treatment: 10 minutes

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

 

Catalog number:

 

KCG50 (50 tests / kit):  Chromogenic Amebocyte Lysate  1.1mL×5

                   (1-3)-β-D-Glucan standard       1mL×2

                   Reconstitution Buffer         10mL×2

                   Tris Buffer                  6mL×1

                   Sample Treatment Solution A   3mL×1

                   Sample Treatment Solution B   3mL×1

 

KCG80 (80 tests / kit):  Chromogenic Amebocyte Lysate  1.7mL×5

                   (1-3)-β-D-Glucan standard       1mL×2

                   Reconstitution Buffer         10mL×2

                   Tris Buffer                  6mL×1

                   Sample Treatment Solution A   3mL×1

                   Sample Treatment Solution B   3mL×1

 

KCG100 (100 tests / kit): Chromogenic Amebocyte Lysate  2.2mL×5

                   (1-3)-β-D-Glucan standard       1mL×2

                   Reconstitution Buffer         10mL×2

                   Tris Buffer                  6mL×1

                   Sample Treatment Solution A   3mL×1

                   Sample Treatment Solution B   3mL×1

 

Product Condition:

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

 


Product detail pictures:

Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo detail pictures

Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo detail pictures


Related Product Guide:

Our solutions are widely regarded and trustworthy by consumers and may meet continually modifying financial and social requirements for Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo , The product will supply to all over the world, such as: Jeddah, Germany, Poland, We are your reliable partner in the international markets of our products. We focus on providing service for our clients as a key element in strengthening our long-term relationships. The continual availability of high grade products in combination with our excellent pre- and after-sales service ensures strong competitiveness in an increasingly globalized market. We are willing to cooperate with business friends from at home and abroad, to create a great future. Welcome to Visit our factory. Looking forward to have win-win cooperation with you.
  • Production management mechanism is completed, quality is guaranteed, high credibility and service let the cooperation is easy, perfect!
    5 Stars By Jean Ascher from San Francisco - 2018.11.06 10:04
    It can be said that this is a best producer we encountered in China in this industry, we feel lucky to work with so excellent manufacturer.
    5 Stars By June from Philippines - 2018.06.05 13:10

    Leave Your Messages

    Related products

    • OEM/ODM Supplier Bacterial Endotoxin Test Kit Suppliers - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      OEM/ODM Supplier Bacterial Endotoxin Test Kit S...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • China Supplier Endotoxin Determination - Control Standard Endotoxin (CSE) – Bioendo

      China Supplier Endotoxin Determination - Contr...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • High definition LAL Turbidimetric detection - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      High definition LAL Turbidimetric detection - ...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...

    • Wholesale Dealers of Bacterial Endotoxin Test Sop - Endotoxin-free Glass Test Tubes – Bioendo

      Wholesale Dealers of Bacterial Endotoxin Test S...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • Super Lowest Price BET Test In Pharma - Rapid Gel Clot single test kit – Bioendo

      Super Lowest Price BET Test In Pharma - Rapid ...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • New Arrival China limulus lysate - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo

      New Arrival China limulus lysate - Endotoxin-s...

      Endotoxin-specific Lyophilized Amebocyte Lysate 1. Product Information Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples ...