Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo


Product Detail

Related Video

Feedback (2)

With a sound business credit, excellent after-sales service and modern manufacturing facilities, we have earned an excellent reputation among our customers across the world for Kit LAL, Bacterial Endotoxin Test In Pharmaceutical, Endotoxin Indicator For Depyrogenation Usp, We've been glad that we have been steadily escalating using the energetic and long lasting assist of our pleased shoppers!
Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo Detail:

Fungi(1,3)-β-D-glucan Assay Kit

Product information:

(1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) measures levels of (1-3)-β-D-Glucan by kinetic chromogenic method. The assay is based upon a modification factor G pathway of the Amebocyte Lysate (AL). (1-3)-β-D-Glucan activates Factor G, the activated Factor G converts the inactive proclotting enzyme to the active clotting enzyme, which in turn cleaves pNA from the chromogenic peptide substrate. pNA is a chromophore that absorbs at 405 nm. The rate of OD increase at 405nm of the reaction solution is directly proportional to the concentration of the reaction solution (1-3)-β-D-Glucan. The concentration of (1-3)-β-D-Glucan in the reaction solution can be calculated according to the standard curve by recording the rate of change of the OD value of the reaction solution through optical detection equipment and software.

The highly sensitive, rapid assay assists clinicians in identifying Invasive Fungal Disease (IFD) early in the disease process. The kit has obtained EU CE qualification and can be used for clinical diagnosis.

 

Immunosuppressed patients are at high risk for developing invasive fungal disease, which is often difficult to diagnose. Affected patient populations include:

Cancer patients undergoing chemotherapy

Stem Cell and Organ Transplant patients

Burn patients

HIV patients

ICU patients

 

Product parameter:

Assay range: 25-1000 pg/ml

Assay time: 40 minutes, sample pre-treatment: 10 minutes

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

 

Catalog number:

 

KCG50 (50 tests / kit):  Chromogenic Amebocyte Lysate  1.1mL×5

                   (1-3)-β-D-Glucan standard       1mL×2

                   Reconstitution Buffer         10mL×2

                   Tris Buffer                  6mL×1

                   Sample Treatment Solution A   3mL×1

                   Sample Treatment Solution B   3mL×1

 

KCG80 (80 tests / kit):  Chromogenic Amebocyte Lysate  1.7mL×5

                   (1-3)-β-D-Glucan standard       1mL×2

                   Reconstitution Buffer         10mL×2

                   Tris Buffer                  6mL×1

                   Sample Treatment Solution A   3mL×1

                   Sample Treatment Solution B   3mL×1

 

KCG100 (100 tests / kit): Chromogenic Amebocyte Lysate  2.2mL×5

                   (1-3)-β-D-Glucan standard       1mL×2

                   Reconstitution Buffer         10mL×2

                   Tris Buffer                  6mL×1

                   Sample Treatment Solution A   3mL×1

                   Sample Treatment Solution B   3mL×1

 

Product Condition:

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

 


Product detail pictures:

Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo detail pictures

Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo detail pictures


Related Product Guide:

Our mission will be to grow to be an innovative supplier of high-tech digital and communication devices by giving worth added design and style, world-class production, and service capabilities for Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo , The product will supply to all over the world, such as: Argentina, Palestine, Barcelona, Our aim is to help customers realize their goals. We are making great efforts to achieve this win-win situation and sincerely welcome you to join us. In a word, when you choose us, you choose a perfect life. Welcome to visit our factory and welcome your order! For further inquiries, please do not hesitate to contact us.
  • This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap.
    5 Stars By Georgia from New Orleans - 2018.11.06 10:04
    This is a very professional and honest Chinese supplier, from now on we fell in love with the Chinese manufacturing.
    5 Stars By Nicole from Turkey - 2018.11.06 10:04

    Leave Your Messages

    Related products

    • Cheap PriceList for Endotoxin free reservoir - Control Standard Endotoxin (CSE) – Bioendo

      Cheap PriceList for Endotoxin free reservoir -...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • Reliable Supplier Endotoxin Detection Assay - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      Reliable Supplier Endotoxin Detection Assay - ...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • OEM Manufacturer Endotoxin Assay Kit - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      OEM Manufacturer Endotoxin Assay Kit - Endotox...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • High reputation 1000ul Pipette tip box - Single-Channel Mechanical Pipettor – Bioendo

      High reputation 1000ul Pipette tip box - Singl...

      Single-Channel Mechanical Pipettor   1. Product Information Single channel mechanical pipette is ideal tool to support endotoxin detection with Lyophilized Amebocyte Lysate which covers gel-clot technique, kinetic turbidimetric technique, kinetic chromogenic technique, and end-point chromogenic technique. All pipettors are produced by following ISO8655 – 2:2002. The quality control involves gravimetric testing of each pipette with distilled water at 22℃.   2. Product Features: - ...

    • OEM China BET Testing - Rapid Gel Clot single test kit – Bioendo

      OEM China BET Testing - Rapid Gel Clot single ...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • Factory Cheap Hot limulus amebocyte - Single-Channel Mechanical Pipettor – Bioendo

      Factory Cheap Hot limulus amebocyte - Single-C...

      Single-Channel Mechanical Pipettor   1. Product Information Single channel mechanical pipette is ideal tool to support endotoxin detection with Lyophilized Amebocyte Lysate which covers gel-clot technique, kinetic turbidimetric technique, kinetic chromogenic technique, and end-point chromogenic technique. All pipettors are produced by following ISO8655 – 2:2002. The quality control involves gravimetric testing of each pipette with distilled water at 22℃.   2. Product Features: - ...