Responsible excellent and fantastic credit rating standing are our principles, which will help us at a top-ranking position. Adhering towards the tenet of "quality initial, buyer supreme" for Chromogenic LAL Endotoxin Assay Kit, Kinetic Turbidimetric LAL kit, Kinetic chromogenic LAL test, We will do our best to meet your requirements and are sincerely looking forward to developing mutual beneficial business relationship with you!
Factory Cheap Hot Kinetic Turbidimetric Endotoxin test Kit - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo Detail:

Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay)

1. Product Introduction

Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.
The kit contains Lyophilized Amebocyte Lysate, Control Standard Endotoxin, and Water for BET. KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) require a kinetic microplate reader such as ELx808IULALXH or a kinetic tube reader. Kinetic software is also required for calculation of the endotoxin concentration.

2. Product Parameter

Assay Range: 0.005 – 5EU/ml; 0.01 – 10EU/ml

3. Product Application

End-product endotoxin (pyrogen) qualification, Waterfor injection endotoxin assay, raw material endotoxin testing or endotoxinlevel monitoring during manufacturing process for pharmaceutical companies ormedical devices manufacturers.

Note:

Lyophilized Amebocyte Lysate reagent manufactured by Bioendo is made from amebocyte lysate from the horseshoe crab (Tachypleus tridentatus).

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

KT0817

Bioendo™ KT Endotoxin Test Kit

(Kinetic Turbidimetric Assay), 128 tests/kit

8 Lyophilized Amebocyte Lysate, 1.7ml (16 Tests/vial);

8 Reconstitution Buffer, 3.0ml/vial;

4 CSE; 2 Water for BET, 50ml/vial;

0.01-10EU/ml

KT0817S

0.005-5EU/ml,

0.01-10EU/ml

KT0852

Bioendo™ KT Endotoxin Test Kit

(Kinetic Turbidimetric Assay), 400 Tests/Kit

8 Lyophilized Amebocyte Lysate, 5.2ml (50 Tests/Vial);

8 Reconstitution Buffer, 6.0ml/vial;

4 CSE; 3 Water for BET, 50ml/vial;

0.01-10EU/ml

KT0852S

0.005-5EU/ml,

0.01-10EU/ml

KT5017

Bioendo™ KT Endotoxin Test Kit

(Kinetic Turbidimetric Assay), 800 Tests/Kit

50 Lyophilized Amebocyte Lysate, 1.7ml (16 Tests/vial);

50 Reconstitution Buffer, 3.0ml/vial; 10 CSE;

0.01-10EU/ml

KT5017S

0.005-5EU/ml,

0.01-10EU/ml

KT5052

Bioendo™ KT Endotoxin Test Kit

(Kinetic Turbidimetric Assay), 2500 Tests/Kit

50 Lyophilized Amebocyte Lysate,5.2ml (50 Tests/vial);

50 Reconstitution Buffer, 6.0ml/vial; 10 CSE;

0.01-10EU/ml

KT5052S

0.005-5EU/ml,

0.01-10EU/ml

Product Condition:

The potency of Lyophilized Amebocyte Lysate and Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis, MSDS.


Product detail pictures:

Factory Cheap Hot Kinetic Turbidimetric Endotoxin test Kit - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures

Factory Cheap Hot Kinetic Turbidimetric Endotoxin test Kit - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures

Factory Cheap Hot Kinetic Turbidimetric Endotoxin test Kit - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures

Factory Cheap Hot Kinetic Turbidimetric Endotoxin test Kit - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures

Factory Cheap Hot Kinetic Turbidimetric Endotoxin test Kit - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures


Related Product Guide:

We have been also specializing in improving the things administration and QC system to ensure that we could preserve terrific gain within the fiercely-competitive company for Factory Cheap Hot Kinetic Turbidimetric Endotoxin test Kit - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo , The product will supply to all over the world, such as: Swiss, Mauritius, Irish, We have more than 200 staff including experienced managers, creative designers, sophisticated engineers and skilled workers. Through hard work of all employees for the past 20 years own company grew stronger and stronger. We always apply the "client first" principle. We also always fulfill all contracts to the point and therefore enjoy excellent reputation and trust among our customers. You are very welcome to personally visit our company.We hope to start a business partnership on the basis of mutual benefit and successful development . For more information please do no hesitate to contact us..
  • The supplier abide the theory of "quality the basic, trust the first and management the advanced" so that they can ensure a reliable product quality and stable customers.
    5 Stars By Meroy from South Korea - 2018.03.03 13:09
    It is a very good, very rare business partners, looking forward to the next more perfect cooperation!
    5 Stars By Roland Jacka from Mongolia - 2017.06.22 12:49

    Leave Your Messages

    Related products

    • New Arrival China Dry heat tunnel validation by ECV - Rapid Gel Clot single test kit – Bioendo

      New Arrival China Dry heat tunnel validation by...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • Low price for Endotoxin Free Tube - Control Standard Endotoxin (CSE) – Bioendo

      Low price for Endotoxin Free Tube - Control St...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • Factory wholesale bacterial endotoxin challenge test - Control Standard Endotoxin (CSE) – Bioendo

      Factory wholesale bacterial endotoxin challenge...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • Discount wholesale BET Endotoxin - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Discount wholesale BET Endotoxin - Beta-glucan...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Factory Cheap Hot LAL test endotoxin - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Factory Cheap Hot LAL test endotoxin - Endotox...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • Manufacturer for Chromogenic endotoxin detection - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      Manufacturer for Chromogenic endotoxin detectio...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...