Discount Price Bacterial Endotoxin Testing - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo


Product Detail

Related Video

Feedback (2)

High-quality comes 1st; support is foremost; business is cooperation" is our small business philosophy which is regularly observed and pursued by our organization for Endotoxin Kit, Endotoxin Detection Methods, Endotoxin Free Microplate, And there are also many foreign friends who came for sight seeing, or entrust us to buy other stuff for them. You are most welcome to come to China, to our city and to our factory!
Discount Price Bacterial Endotoxin Testing - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo Detail:

 Endotoxin Challenge Vials (Endotoxin Indicator)

 

1. Product Information

The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3-log reduction in endotoxin content when tested using gel clot endotoxin assay kit, kinetic turbidimetric endotoxin assay kit or chromogenic Lyophilized Amebocyte Lysate assay kits. Endotoxin Challenge Vial contains 1000 to 10000EU Endotoxins level in a glass vial. ECV1250V and ECV2500V are sealed in vials that configurate the heat resistant stoppers and heat resistant labels, which could be placed in dry-heat oven or dry-heat tunnel without removal of stoppers and caps(lid).

Validation of dry heat sterilization cycle(s) is required by regulations of ANSI, AAMI, ISO, USP and FDA to ensure that all items that are required to be sterile or endotoxin-free are able to consistently and reliably be sterilized to reduce the chance of introducing or spreading an infectious micro-organism or pyrogens.

Follow the Regulations requirement, use Bioendo ECV is able to operate the endotoxin free validation or pyrogen free validation. More important information is Bioendo ECV no need rubber lid(cap) removal in the heating operation.

 

2. Product Parameter

The potency: 1000 to 10000 EU per vial and 2000 to 10000 EU in a vial.  

 

3. Product Features and Application

In vial with heat resistant stopper (tolerable high temperature up to 360 Celsius degree) and heat resistant label. 

In the procedure of baking or drying, ECV vial’s lid no need to remove. 

Without excipient.  

Endotoxin Challenge Vial  (10ml glass bottle and 2ml of ISO standard 2R glass bottle)

Catalog No.

Endotoxins Level (EU/vial)

Package

ECV1250V

1000-10000

In Vial, 10 Vials/Pack

ECV1250VR

 1000-10000

ISO 2R vial, 10 Vials/Pack

ECV2500V

2000-10000

In Vial, 10 Vials/Pack

ECV2500VR

 2000-10000

ISO 2R vial, 10 Vials/Pack

ECV100000V

50000-200000

In Vial, 10 Vials/Pack

How is the features of Bioendo’s Endotoxin Challenge Vails (Endotoxin Indicator)?

Endotoxin challenge vial, in the operation procedures, the lysate reagent has to match the ECV kit, and no need remove the lit during the baking procedure.


Product detail pictures:

Discount Price Bacterial Endotoxin Testing - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo detail pictures

Discount Price Bacterial Endotoxin Testing - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo detail pictures

Discount Price Bacterial Endotoxin Testing - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo detail pictures

Discount Price Bacterial Endotoxin Testing - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo detail pictures


Related Product Guide:

With this motto in mind, we've got become among essentially the most technologically innovative, cost-efficient, and price-competitive manufacturers for Discount Price Bacterial Endotoxin Testing - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo , The product will supply to all over the world, such as: Estonia, Latvia, US, You can let us know your idea to develop unique design for your own model to prevent too much similar parts in the market! We will provide our best service to satisfy all your needs! You should contact us right away!
  • In general, we are satisfied with all aspects, cheap, high-quality, fast delivery and good procuct style, we will have follow-up cooperation!
    5 Stars By Helen from Porto - 2017.10.27 12:12
    It is really lucky to meet such a good supplier, this is our most satisfied cooperation, I think we will work again!
    5 Stars By Jack from Vietnam - 2018.11.02 11:11

    Leave Your Messages

    Related products

    • Manufacturer of Dry Heat Sterilization Validation – Compact Modular Dry Heat Incubator – Bioendo

      Manufacturer of Dry Heat Sterilization Validati...

      Dry Heat Incubator 1. Product description: Dry Heat Incubator TAL-M2 is amicroprocessor-controlled device, high precision of temperature control, samplepreparation parallelism, as an alternative to the traditional water bathdevice. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules. TAL- M2 A Dry bath incubat...

    • High reputation 1000ul Pipette tip box - Mini Dry Heat Incubator – Bioendo

      High reputation 1000ul Pipette tip box - Mini ...

      Dry heat incubator single module 1. Product information  The Mini Dry Heat Incubator is a micro-processor controlled heating block with semi conductor heating technology.It adapts onboard use, smart, light and convenient for movement, suit for any kind of occasions. Especially good for the incubation of the gel clot LAL assay, LAL chromogenic endpoint assay incubation. 2. Product features 1. Unique designed. Smart and light, convenient movement, suit for various occasions. 2. LCD simultaneou...

    • Chinese Professional Chromogenic assays - Endpoint Chromogenic Kit EC64405 – Bioendo

      Chinese Professional Chromogenic assays - Endp...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • Professional China bacterial endotoxin test - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      Professional China bacterial endotoxin test - ...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • Factory made hot-sale Bacterial Endotoxin Test Validation - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Factory made hot-sale Bacterial Endotoxin Test ...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

    • Hot New Products Kinetic chromogenic TAL test kit - Endpoint Chromogenic Kit EC64405 – Bioendo

      Hot New Products Kinetic chromogenic TAL test k...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...