Chinese wholesale Chromogenic endotoxin assay - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo


Product Detail

Related Video

Feedback (2)

Our advancement depends over the superior machines, exceptional talents and continually strengthened technology forces for Kinetic Chromogenic Endotoxin test kit, Chromogenic assays, Bacterial Endotoxin Test Gel Clot Method, Our professional technical team will be wholeheartedly at your service. We sincerely welcome you to visit our website and company and send us your inquiry.
Chinese wholesale Chromogenic endotoxin assay - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo Detail:

 Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay)

The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit meets the requirements of the rules of Bacterial Endotoxin Test in Pharmacopoeia. Each test requires only the 25μL sample for test and 25μL of lysate reagent. The testing principle is the same as that of the traditional kinetic chromogenic method for endotoxin detection. It has strong anti-interference ability and is very suitable for endotoxins quantitative detection in parenteral drugs, vaccines, antibodies, biological preparations and so on.

Typical users:

Pharmaceutical manufacturers, medical devices manufacturers, scientific research institutions.

Ø Less dosage of sample for test , and each test only needs 25μL of samples for testing.
Ø Adopting the pharmacopoeia-approved kinetic chromogenic method technology which can meet the requirements of GMP for data integrity and traceability.
Ø High sensitivity, up to 0.005EU/ml.
Ø Strong anti-interference ability, does not require coagulogen to form a gel, and accurately quantifies bacterial endotoxins based on the color reaction.
Ø Easy to operate, complete 96 tests at one time, and the system automatically detects and analyzes in one step.
Ø High cost-effective, higher performance.
Ø Supporting 8-well plate for micro-detection

 

Technical Parameters: 

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

MKC0505VS

Bioendo™ KC Endotoxin Test Kit (Micro Kinetic Chromogenic Assay), 90 Tests/Kit

5 Chromogenic Amebocyte Lysate, 0.5ml (18 Tests/Vial);

5 Reconstitution Buffer, 2.0ml/vial; 

0.005 to 5EU/ml

MKC0505V

0.01 to 10EU/ml

MKC0505AS

Bioendo™ KC Endotoxin Test Kit (Micro Kinetic Chromogenic Assay), 90 Tests/Kit

5 Chromogenic Amebocyte Lysate, 0.5ml (18 Tests/ampoule);

5 Reconstitution Buffer, 2.0ml/vial; 

0.005 to 5EU/ml

MKC0505A

0.01 to 10EU/ml

MPMC96

8 wells per strip

96 wells per microplate, 12pcs detachable strips.

 

What is the main feature of new Bioendo microKC kit?

Each test requires only the 25μL sample for test and 25μL of lysate reagent. Provide the professional solution that is very friendly in terms of resource utilization. 

 

Endotoxin free microplates MPMC96: the strip is individual wrap, 8 wells a strips, provide economical solution for the micro kinetic chromogenic assay.
Kinetic microplate reader Elx808 or others Elx808 series.

Pyrogen free microplate

 


Product detail pictures:

Chinese wholesale Chromogenic endotoxin assay - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo detail pictures

Chinese wholesale Chromogenic endotoxin assay - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo detail pictures

Chinese wholesale Chromogenic endotoxin assay - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo detail pictures

Chinese wholesale Chromogenic endotoxin assay - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo detail pictures


Related Product Guide:

Along with the "Client-Oriented" small business philosophy, a rigorous high-quality handle system, highly developed producing machines and a powerful R&D group, we always supply high-quality products and solutions, fantastic services and aggressive costs for Chinese wholesale Chromogenic endotoxin assay - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo , The product will supply to all over the world, such as: Mombasa, Iraq, Kyrgyzstan, Please really feel free to send us your requirements and we'll respond to you asap. We have got a professional engineering group to serve for your just about every detailed needs. Cost-free samples could be sent for you personally to understand much more information. In an effort to meet your requires, please really feel free to make contact with us. You may send us emails and contact us directly. Moreover, we welcome visits to our factory from around the globe for much better recognizing of our organization. nd items. In our trade with merchants of numerous countries, we usually adhere for the principle of equality and mutual benefit. It is actually our hope to market, by joint efforts, each trade and friendship to our mutual advantage. We look forward to getting your inquiries.
  • This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
    5 Stars By Nick from Latvia - 2017.02.28 14:19
    The sales person is professional and responsible, warm and polite, we had a pleasant conversation and no language barriers on communication.
    5 Stars By Grace from South Korea - 2018.07.27 12:26

    Leave Your Messages

    Related products

    • Chinese wholesale LAL endotoxin assay kit - Depyrogenated Sample Bottles ( Endotoxin Free ) – Bioendo

      Chinese wholesale LAL endotoxin assay kit - De...

      Depyrogenated Sample Container 1. Product information We offer various of low endotoxin, pyrogen free accessories products,includes Water for Bacterial Endotoxins Test, pyrogen-free test tubes, pyrogen-free pipettor tips, microplates and sample bottles for your conveniences. High quality depyrogenated low endotoxin pyrogen free products insure the success of your experiments. Depyrogenated (Endotoxin Free) Sample container(endotoxin free bottle, pyrogen free bottle, pyrogen free sample bot...

    • Reasonable price Turbidimetric LAL assay - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      Reasonable price Turbidimetric LAL assay - Kin...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...

    • factory Outlets for Endotoxin Of Bacteria - Endotoxin-free Glass Test Tubes – Bioendo

      factory Outlets for Endotoxin Of Bacteria - En...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • High reputation Endotoxin free tip box - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      High reputation Endotoxin free tip box - Endot...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • Competitive Price for Endotoxin Is Produced By - Endotoxin-free Glass Test Tubes – Bioendo

      Competitive Price for Endotoxin Is Produced By ...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • Trending Products Bacterial Endotoxin Test For Water For Injection - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Trending Products Bacterial Endotoxin Test For ...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...