China wholesale LAL gel clot - Bioendo GC Endotoxin Test Kit (Gel Clot Assay) – Bioendo


Product Detail

Related Video

Feedback (2)

Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" as well as theory of "quality the basic, have faith in the initial and administration the advanced" for Kinetic chromogenic TAL test kit, endotoxin testing, Pyrogen free microplate, In order to expand our international market, we mainly supply our oversea customers Top quality performance products and service.
China wholesale LAL gel clot - Bioendo GC Endotoxin Test Kit (Gel Clot Assay) – Bioendo Detail:

Bioendo GC Endotoxin Test Kit

Bioendo GC Endotoxin Test Kit (Gel Clot Assay) 

1. Product Information

Bioendo GC Endotoxin Test Kit (Gel Clot Assay) contains 128 Tests/Kit, 400Tests/Kit, 1600Tests/Kit, and 4500 Tests/Kit. And sensitivity of Amebocyte Lysate included by the Kit is 0.03 EU/ml, 0.06 EU/ml, 0.125 EU/ml, 0.25 EU/ml, 0.5 EU/ml. The Kit contains Amebocyte Lysate, CSE and Water for BET. Four kinds of configuration of gel-clot endotoxin assay kit to satisfied the demand. This means you could choose different configuration kits according to the requirement. 

2. Product Parameter 

Sensitivities: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5 EU/ml

3.Product Feature and Application

Full range of sensitivities to meet the demand. No special instrument is needed for endotoxin detection with Bioendo GC Endotoxin Test Kit (Gel Clot Assay). It is the best choice when you need to do lots of endotoxin detection.

Note:

Lyophilized Amebocyte Lysate (LAL/TAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Sensitivity (EU/ml)

Description

Kit Contents

GC90520030

0.03

Bioendo™ GC Endotoxin Test Kit (Gel Clot Assay)

4500 Tests/Kit

90 Gel Clot Lyophilized Amebocyte Lysate,

5.2ml (50 Tests/Vial);

20 CSE10V;

GC90520060

0.06

GC90520125

0.125

GC90520250

0.25

GC90520500

0.5

GC08520030

0.03

Bioendo™ GC Endotoxin

Test Kit (Gel Clot Assay)

400 Tests/Kit

8 Gel Clot Lyophilized Amebocyte Lysate,

5.2ml (50 Tests/Vial);

4 CSE10V;

2 Water for BET, 50ml/vial;

GC08520060

0.06

GC08520125

0.125

GC08520250

0.25

GC08520500

0.5

GC100170030

0.03

Bioendo™ GC Endotoxin Test Kit (Gel Clot Assay)

1600 Tests/Kit

100 Gel Clot Lyophilized Amebocyte Lysate, 1.7ml (16 Tests/Vial);

10 CSE10V;

GC100170060

0.06

GC100170125

0.125

GC100170250

0.25

GC100170500

0.5

GC08170030

0.03

Bioendo™ GC Endotoxin Test Kit (Gel Clot Assay)

128 Tests/Kit

8 Gel Clot Lyophilized Amebocyte Lysate,

1.7ml (16 Tests/Vial);

4 CSE10V;

2 Water for BET, 50ml/vial;

GC08170060

0.06

GC08170125

0.125

GC08170250

0.25

GC08170500

0.5

Product condition:

Endotoxin Test kit’s sensitivity and the Control Standard Endotoxin potency are assayed against USP Reference Standard Endotoxin. The Endotoxin Test reagentkits come with product instruction, Certificate of Analysis.


Product detail pictures:

China wholesale LAL gel clot - Bioendo GC Endotoxin Test Kit (Gel Clot Assay) – Bioendo detail pictures

China wholesale LAL gel clot - Bioendo GC Endotoxin Test Kit (Gel Clot Assay) – Bioendo detail pictures

China wholesale LAL gel clot - Bioendo GC Endotoxin Test Kit (Gel Clot Assay) – Bioendo detail pictures


Related Product Guide:

Our purpose would be to offer good quality products at competitive price ranges, and top-notch support to clients around the whole world. We're ISO9001, CE, and GS certified and strictly adhere to their good quality specifications for China wholesale LAL gel clot - Bioendo GC Endotoxin Test Kit (Gel Clot Assay) – Bioendo , The product will supply to all over the world, such as: Juventus, Slovenia, Maldives, Welcome to visit our company and factory, there are various products displayed in our showroom that will meet your expectation, meanwhile, if you are convenient to visit our website, our sales staff will try their efforts to provide you the best service
  • This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
    5 Stars By King from Uganda - 2017.11.11 11:41
    The factory technical staff not only have high level of technology, their English level is also very good, this is a great help to technology communication.
    5 Stars By Amelia from Ecuador - 2018.06.05 13:10

    Leave Your Messages

    Related products

    • New Arrival China Kinetic Turbidimetric Method endotoxin - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      New Arrival China Kinetic Turbidimetric Method ...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...

    • OEM China Endotoxin Detection Kit - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      OEM China Endotoxin Detection Kit - Beta-gluca...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • OEM/ODM Factory Bioendo Endotoxin - Control Standard Endotoxin (CSE) – Bioendo

      OEM/ODM Factory Bioendo Endotoxin - Control St...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • Well-designed Bacterial Endotoxin Calculation - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Well-designed Bacterial Endotoxin Calculation -...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • High Quality LAL Reagent - Pyrogen-free Centrifuge Tube – Bioendo

      High Quality LAL Reagent - Pyrogen-free Centri...

      Pyrogen-free Centrifuge Tube   Product features: * Pyrogen-free Centrifuge tube is made from virgin polypropylene to meet the general requirements of the laboratory. * Pyrogen-free, Endotoxin level <0.005EU/ml * High strength non-toxic materials * Printed clear graduations with marking area * Gamma Radiation Sterilized * 50ml Maximum RCF is 18000g, 15ml Maximum RCF is 12000g * DNase/RNase free * Autoclavable * Temperature range is -20°C to 121°C * Leak-proof * Cap 50% longer ideal for avo...

    • Top Suppliers Dry Heat Sterilizer Validation - Single-Channel Mechanical Pipettor – Bioendo

      Top Suppliers Dry Heat Sterilizer Validation -...

      Single-Channel Mechanical Pipettor   1. Product Information Single channel mechanical pipette is ideal tool to support endotoxin detection with Lyophilized Amebocyte Lysate which covers gel-clot technique, kinetic turbidimetric technique, kinetic chromogenic technique, and end-point chromogenic technique. All pipettors are produced by following ISO8655 – 2:2002. The quality control involves gravimetric testing of each pipette with distilled water at 22℃.   2. Product Features: - ...