Bottom price 250ul Pipette tip box - Rapid Gel Clot single test kit – Bioendo


Product Detail

Related Video

Feedback (2)

we could supply good quality goods, aggressive cost and very best purchaser assistance. Our destination is "You come here with difficulty and we supply you with a smile to take away" for BET Endotoxin, BET Endotoxin, Bacterial Endotoxin Test Kinetic Turbidimetric Method, We persistently develop our enterprise spirit "quality lives the business, credit score assures cooperation and retain the motto inside our minds: consumers very first.
Bottom price 250ul Pipette tip box - Rapid Gel Clot single test kit – Bioendo Detail:

Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit)

1. Product Information

Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes.
Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures in the operation of rapid endotoxin assay, the whole operation not required sophisticated experimental equipment, incubation by a dry heat incubator. It is especial suitable for the endotoxins analysis in the water or dialysate.

20190819091605_48802

2. Product Parameter

Sensitivity Range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5EU/ml

One sample test in a kit. 

Assay time: less than 30 minutes. 

Catalog No.

Description

Kit Contents

Sensitivity

EU/ml

Reaction Time

minutes

RG025003

BioendoTM Rapid Gel Clot Endotoxin Assay Kit, One Sample Kit

1 SPL Tube;

1 PPC Tube;

1 Endotoxin-free Sample Bottle;

3 Pyrogen-free Pipettors;

0.03

≤60

RG025006

0.06

≤60

RG0250125

0.125

≤45

RG025025

0.25

≤30

RG025050

0.5

≤30

 

3. Kit Application

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit provide a kind of rapid endotoxin testing solution, the featured application in the field of dialysis. 

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab. In the operation procedure,  the dilution of control standard endotoxin is simple and convenient. Endotoxin free sample container and pyrogen free transfer pipette is required, Sophisticated instrument is not required, recommend Bioendo Dry heat incubator TAL-MT use in the procedure of incubation. 

Kit Configuration:

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit contains: 

1 piece of SPL Tube, 1 piece of PPC Tube, 1 piece of Endotoxin-free Sample Bottle. (endotoxin free top level), 

1 Pack of Transfer Pipette 3 pieces. (endotoxin free top level)


Product detail pictures:

Bottom price 250ul Pipette tip box - Rapid Gel Clot single test kit – Bioendo detail pictures

Bottom price 250ul Pipette tip box - Rapid Gel Clot single test kit – Bioendo detail pictures

Bottom price 250ul Pipette tip box - Rapid Gel Clot single test kit – Bioendo detail pictures

Bottom price 250ul Pipette tip box - Rapid Gel Clot single test kit – Bioendo detail pictures

Bottom price 250ul Pipette tip box - Rapid Gel Clot single test kit – Bioendo detail pictures


Related Product Guide:

Trustworthy good quality and excellent credit score standing are our principles, which will help us at a top-ranking position. Adhering towards the tenet of "quality first, buyer supreme" for Bottom price 250ul Pipette tip box - Rapid Gel Clot single test kit – Bioendo , The product will supply to all over the world, such as: Kuwait, Seattle, Frankfurt, we have all day online sales to make sure the pre-sale and after-sale service in time. With all these supports, we can serve every customer with quality product and timely shipping with highly responsibility. Being a young growing company, we might not the best, but we are trying our best to be your good partner.
  • The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
    5 Stars By Jean from Malawi - 2018.10.31 10:02
    High Quality, High Efficiency, Creative and Integrity, worth having long-term cooperation! Looking forward to the future cooperation!
    5 Stars By Odelette from Jordan - 2017.09.22 11:32

    Leave Your Messages

    Related products

    • Manufacturer for LAL reagent manufacturer - Single-Channel Mechanical Pipettes (Semi-sterile) – Bioendo

      Manufacturer for LAL reagent manufacturer - Si...

      Single-Channel Mechanical Pipettes (Semi-sterile)   1. Product Information The Single-Channel Mechanical Pipettes (Semi-sterile) is adjustable, which could be used to dispense liquid precisely. Measuring volume of our Single-Channel Mechanical Pipettes (Semi-sterile) ranges from 0.1μL to 5mL. Products are produced based on ISO8655/DIN12650. It could be widely employed on endotoxin detection, etc..   2. Product Features - Light weight, economic - The pipettes cover volume range from 0.1μL to 5...

    • High definition Kinetic chromogenic LAL Assay - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo

      High definition Kinetic chromogenic LAL Assay -...

       Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay) The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit mee...

    • Bottom price 250ul Pipette tip box - Rapid Gel Clot single test kit – Bioendo

      Bottom price 250ul Pipette tip box - Rapid Gel...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • OEM China BET Testing - Endotoxin Assay and (1,3)-ß-D-glucan assay software – Bioendo

      OEM China BET Testing - Endotoxin Assay and (1...

      Endotoxin and (1,3)-ß-D-glucan assay software 1. Product information Endotoxin and (1,3)-ß-D-glucan assay software is a powerful kinetic data analysis software,which gives the user data acquisition and processing of the maximum flexibility. Features: • Apply to Endotoxin assay,(1,3)-ß-D-glucan assay and ELISA data analysis • With standard version and clinical diagnostic version for the different user groups. • Data could be output transitions and connected to the LIS system. • Customizabl...

    • High definition Pipette tip - Rapid Gel Clot 10 Samples Kit – Bioendo

      High definition Pipette tip - Rapid Gel Clot 1...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Bottom price Endotoxin free test tube - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Bottom price Endotoxin free test tube - Beta-g...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...