Best quality limulus lysate assay - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo


Product Detail

Related Video

Feedback (2)

We strive for excellence, service the customers", hopes to become the best cooperation team and dominator enterprise for personnel, suppliers and customers, realizes value share and continuous promotion for Kinetic Chromogenic Endotoxin Assay Kit, Chromogenic assays, LAL Turbidimetric detection, We welcome new and old customers from all walks of life to contact us for future business relationships and achieving mutual success!
Best quality limulus lysate assay - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo Detail:

Endotoxin-specific Lyophilized Amebocyte Lysate

1. Product Information
Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples with potential which are contaminated by ß-Glucan. Bioendo has two Endotoxin-specific Lyophilized Amebocyte Lysate. One is that operator needs to add 0.1ml Water for BET and 0.1ml sample solution to the ampoule of Endotoxin-specific Lyophilized Amebocyte Lysate respectively; the other is that 0.2ml sample solution could be added directly into the ampoule.

2. Product Parameter
Sensitivity range: 0.03, 0.06, 0.125, 0.25, 0.5EU/ml

3. Product Application

Endotoxin-specific Lyophilized Amebocyte Lysate is the optimal choice for endotoxin detection of samples contaminated by beta-glucan such as cellulose, fungi solution.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Sensitivity (EU/ml)

ES010030

0.03

ES010060

0.06

ES010125

0.125

ES010250

0.25

ES010500

0.5

Product Condition: 

The sensitivity of Lyophilized Amebocyte Lysate and Control Standard Endotoxin potency are assayed against USP Reference Standard Endotoxin. Lyophilized Amebocyte Lysate kit comes with product instruction, Certificate of Analysis, MSDS. 

Lysate reagent + Matched Control standard endotoxin ( save cost than RSE, CSE vial is calibrated by RSE. )

BET water or called LAL reagent water

Endotoxin free tubes and tips

Above all materials are necessary in the operation of endotoxin test assay.


Product detail pictures:

Best quality limulus lysate assay - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo detail pictures

Best quality limulus lysate assay - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo detail pictures

Best quality limulus lysate assay - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo detail pictures


Related Product Guide:

We have now a hugely efficient team to deal with inquiries from buyers. Our goal is "100% client gratification by our solution high-quality, rate & our team service" and take pleasure in a great popularity among clients. With several factories, we will provide a wide assortment of Best quality limulus lysate assay - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo , The product will supply to all over the world, such as: Belarus, Rome, Singapore, With the superior and exceptional service, we've been well developed along with our customers. Expertise and know-how ensure that we are always enjoying the trust from our customers in our business activities. "Quality", "honesty" and "service" is our principle. Our loyalty and commitments remain respectfully at your service. Contact Us Today For further information, contact us now.
  • This manufacturers not only respected our choice and requirements, but also gave us a lot of good suggestions, ultimately, we successfully completed the procurement tasks.
    5 Stars By Penelope from Singapore - 2018.12.28 15:18
    This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap.
    5 Stars By Hazel from Australia - 2017.12.31 14:53

    Leave Your Messages

    Related products

    • High reputation 1000ul Pipette tip box - Rapid Gel Clot 10 Samples Kit – Bioendo

      High reputation 1000ul Pipette tip box - Rapid...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • 100% Original Chromogenic Endotoxin Quant Kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      100% Original Chromogenic Endotoxin Quant Kit -...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...

    • 2022 wholesale price TAL assay - Rapid Gel Clot single test kit – Bioendo

      2022 wholesale price TAL assay - Rapid Gel Clo...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • High Quality LAL Reagent - Rapid Gel Clot 10 Samples Kit – Bioendo

      High Quality LAL Reagent - Rapid Gel Clot 10 S...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Wholesale Price China Kinetic Turbidimetric LAL kit for endotoxin detection - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      Wholesale Price China Kinetic Turbidimetric LAL...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • Manufactur standard Endotoxin Lps - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Manufactur standard Endotoxin Lps - Endotoxin ...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...