Our progress depends about the advanced products ,fantastic talents and continuously strengthened technology forces for Endotoxin, Depyrogenated microplate, Bacterial Endotoxin Limit For API, The concept of our company is "Sincerity, Speed, Service, and Satisfaction". We will follow this concept and win more and more customers' satisfaction.
Best quality limulus lysate assay - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo Detail:

Endotoxin-specific Lyophilized Amebocyte Lysate

1. Product Information
Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples with potential which are contaminated by ß-Glucan. Bioendo has two Endotoxin-specific Lyophilized Amebocyte Lysate. One is that operator needs to add 0.1ml Water for BET and 0.1ml sample solution to the ampoule of Endotoxin-specific Lyophilized Amebocyte Lysate respectively; the other is that 0.2ml sample solution could be added directly into the ampoule.

2. Product Parameter
Sensitivity range: 0.03, 0.06, 0.125, 0.25, 0.5EU/ml

3. Product Application

Endotoxin-specific Lyophilized Amebocyte Lysate is the optimal choice for endotoxin detection of samples contaminated by beta-glucan such as cellulose, fungi solution.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Sensitivity (EU/ml)

ES010030

0.03

ES010060

0.06

ES010125

0.125

ES010250

0.25

ES010500

0.5

Product Condition: 

The sensitivity of Lyophilized Amebocyte Lysate and Control Standard Endotoxin potency are assayed against USP Reference Standard Endotoxin. Lyophilized Amebocyte Lysate kit comes with product instruction, Certificate of Analysis, MSDS. 

Lysate reagent + Matched Control standard endotoxin ( save cost than RSE, CSE vial is calibrated by RSE. )

BET water or called LAL reagent water

Endotoxin free tubes and tips

Above all materials are necessary in the operation of endotoxin test assay.


Product detail pictures:

Best quality limulus lysate assay - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo detail pictures

Best quality limulus lysate assay - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo detail pictures

Best quality limulus lysate assay - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo detail pictures


Related Product Guide:

It is our responsibility to meet your needs and efficiently serve you. Your satisfaction is our best reward. We are looking forward to your visit for joint growth for Best quality limulus lysate assay - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo , The product will supply to all over the world, such as: Cannes, Seychelles, Hongkong, Most problems between suppliers and clients are due to poor communication. Culturally, suppliers can be reluctant to question things they do not understand. We break down those barriers to ensure you get what you want to the level you expect, when you want it. Faster delivery time and the product you want is our Criterion .
  • This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
    5 Stars By Gail from Macedonia - 2017.11.11 11:41
    Goods just received, we are very satisfied, a very good supplier, hope to make persistent efforts to do better.
    5 Stars By Kristin from Georgia - 2018.07.26 16:51

    Leave Your Messages

    Related products

    • Popular Design for Endotoxin Indicator For Depyrogenation - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Popular Design for Endotoxin Indicator For Depy...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • High reputation 1000ul Pipette tip box - Rapid Gel Clot 10 Samples Kit – Bioendo

      High reputation 1000ul Pipette tip box - Rapid...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • China Cheap price LAL endotoxin - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      China Cheap price LAL endotoxin - Beta-glucans...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Factory Supply Endotoxin Free Water - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Factory Supply Endotoxin Free Water - Beta-glu...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Wholesale Kinetic chromogenic LAL test kit - Endpoint Chromogenic Kit EC64405 – Bioendo

      Wholesale Kinetic chromogenic LAL test kit - E...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • Manufacturer of Dry Heat Sterilization Validation – Rapid Gel Clot single test kit – Bioendo

      Manufacturer of Dry Heat Sterilization Validati...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...