Best quality Endotoxin Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo


Product Detail

Related Video

Feedback (2)

We've got quite possibly the most state-of-the-art production gear, experienced and qualified engineers and workers, acknowledged top quality handle systems along with a friendly expert gross sales group pre/after-sales support for Kinetic Chromogenic Endotoxin test kit, Chromogenic endotoxin test, Dry heat sterilizer validation by ECV, We hope we can have a friendly relationship with businessman from all over the world.
Best quality Endotoxin Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo Detail:

Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial

1. Product Information

Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in Vial, you could add sample to the vial directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many vials use each time to avoid waste. Endotoxin free tube for dilution of CSE is necessary. Operation of endotoxin detection by choice of Bioendo Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial conforms to the USP, the EP.

2. Product Parameter

Gel clot assay single test glass vial

Sensitivities:  0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25 EU/ml

3.Product Feature and Application

Single step endotoxin detection,

without expensive endotoxin assay instruments,

Suitable for end-product endotoxin testing before product released,

Product sensitivity standardized according to US Pharmacopoeia criterion and China Pharmacopoeia criterion.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from lysate of amebocytes (white blood cells) from the horseshoe crab.

Catalog number Sensitivity (EU/ml) (IU/ml) Tests/Vial Vials/Pack
G020015 0.015 1 50
G020030 0.03 1 50
G020060 0.06 1 50
G020125 0.125 1 50
G020250 0.25 1 50
G020500 0.5 1 50

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

Why the most selected gel clot assay kit G02:

1. The most economical and commonly used test reagent for endotoxin detection.

2. Single test in a vial for one stepping reduce the risk of contamination.

3. Gel clot assay single test glass vial no need sophisticated microplate reader.

4. Saving endotoxin free tube when using G02 series to test endotoxins in the procedure of endotoxin test assay’s operation.

Related products in the endotoxin test assay:
Water for Bacterial Endotoxins Test (BET),  Recommend TRW50 or TRW100
Endotoxin free glass tube ( dilution tube ),  Recommend T1310018
Pyrogen free tips,  Recommend PT25096 or PT100096
Pipettor, Recommend PSB0220
Test Tube Rack,
Incubation Instrument (Water Bath or Dry Heat Incubator ), Recommend Dry Heat Incubator TAL-M2
Vortex Mixter, Recommend VXH.
Control Standard Endotoxin, CSE10V.

Product detail pictures:

Best quality Endotoxin Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures

Best quality Endotoxin Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures

Best quality Endotoxin Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures

Best quality Endotoxin Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures

Best quality Endotoxin Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures

Best quality Endotoxin Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures


Related Product Guide:

While in the past few years, our organization absorbed and digested innovative technologies both equally at home and abroad. Meanwhile, our organization staffs a group of experts devoted for the advancement of Best quality Endotoxin Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo , The product will supply to all over the world, such as: Bangladesh, Islamabad, Doha, For more than ten years experience in this filed, our company has gained high reputation from home and abroad. So we welcome friends from all over the world to come and contact us, not only for business, but also for friendship.
  • Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
    5 Stars By Katherine from Hongkong - 2017.08.15 12:36
    High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.
    5 Stars By Sarah from Belgium - 2018.09.08 17:09

    Leave Your Messages

    Related products

    • High reputation 1000ul Pipette tip box - Single-Channel Mechanical Pipettor – Bioendo

      High reputation 1000ul Pipette tip box - Singl...

      Single-Channel Mechanical Pipettor   1. Product Information Single channel mechanical pipette is ideal tool to support endotoxin detection with Lyophilized Amebocyte Lysate which covers gel-clot technique, kinetic turbidimetric technique, kinetic chromogenic technique, and end-point chromogenic technique. All pipettors are produced by following ISO8655 – 2:2002. The quality control involves gravimetric testing of each pipette with distilled water at 22℃.   2. Product Features: - ...

    • 2022 wholesale price Kinetic Turbidimetric vs Kinetic Chromogenic - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      2022 wholesale price Kinetic Turbidimetric vs K...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...

    • Best Price for Endotoxin Indicator For Depyrogenation Usp - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Best Price for Endotoxin Indicator For Depyroge...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Low price for Pipettor tip box - Rapid Gel Clot 10 Samples Kit – Bioendo

      Low price for Pipettor tip box - Rapid Gel Clo...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Short Lead Time for Endotoxin Assay LAL - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      Short Lead Time for Endotoxin Assay LAL - Pyro...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • Chinese Professional Chromogenic assays - Endpoint Chromogenic Kit EC80545 – Bioendo

      Chinese Professional Chromogenic assays - Endp...

      Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) 1. Product Information Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum abso...