We love an incredibly fantastic standing amid our consumers for our superb item high quality, aggressive rate and also the finest assistance for Endotoxin Gel Clot, Endotoxin Activity Assay, Detection Of Endotoxin, "Quality 1st, Rate least expensive, Provider best" is definitely the spirit of our company. We sincerely welcome you to go to our business and negotiate mutual small business!
8 Year Exporter Define LAL Test - Rapid Gel Clot single test kit – Bioendo Detail:

Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit)

1. Product Information

Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes.
Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures in the operation of rapid endotoxin assay, the whole operation not required sophisticated experimental equipment, incubation by a dry heat incubator. It is especial suitable for the endotoxins analysis in the water or dialysate.

20190819091605_48802

2. Product Parameter

Sensitivity Range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5EU/ml

One sample test in a kit. 

Assay time: less than 30 minutes. 

Catalog No.

Description

Kit Contents

Sensitivity

EU/ml

Reaction Time

minutes

RG025003

BioendoTM Rapid Gel Clot Endotoxin Assay Kit, One Sample Kit

1 SPL Tube;

1 PPC Tube;

1 Endotoxin-free Sample Bottle;

3 Pyrogen-free Pipettors;

0.03

≤60

RG025006

0.06

≤60

RG0250125

0.125

≤45

RG025025

0.25

≤30

RG025050

0.5

≤30

 

3. Kit Application

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit provide a kind of rapid endotoxin testing solution, the featured application in the field of dialysis. 

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab. In the operation procedure,  the dilution of control standard endotoxin is simple and convenient. Endotoxin free sample container and pyrogen free transfer pipette is required, Sophisticated instrument is not required, recommend Bioendo Dry heat incubator TAL-MT use in the procedure of incubation. 

Kit Configuration:

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit contains: 

1 piece of SPL Tube, 1 piece of PPC Tube, 1 piece of Endotoxin-free Sample Bottle. (endotoxin free top level), 

1 Pack of Transfer Pipette 3 pieces. (endotoxin free top level)


Product detail pictures:

8 Year Exporter Define LAL Test - Rapid Gel Clot single test kit – Bioendo detail pictures

8 Year Exporter Define LAL Test - Rapid Gel Clot single test kit – Bioendo detail pictures

8 Year Exporter Define LAL Test - Rapid Gel Clot single test kit – Bioendo detail pictures

8 Year Exporter Define LAL Test - Rapid Gel Clot single test kit – Bioendo detail pictures

8 Year Exporter Define LAL Test - Rapid Gel Clot single test kit – Bioendo detail pictures


Related Product Guide:

We have now numerous great personnel members good at advertising, QC, and working with kinds of troublesome dilemma from the creation course of action for 8 Year Exporter Define LAL Test - Rapid Gel Clot single test kit – Bioendo , The product will supply to all over the world, such as: Argentina, Argentina, Madagascar, Our aim is to help customers realize their goals. We have been making great efforts to achieve this win-win situation and sincerely welcome you to join us. In a word, when you choose us, you choose a perfect life. Welcome to visit our factory and welcome your order! For further inquiries, you should do not hesitate to contact us.
  • Perfect services, quality products and competitive prices, we have work many times, every time is delighted, wish continue to maintain!
    5 Stars By Michelle from Lisbon - 2017.12.02 14:11
    This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap.
    5 Stars By Liz from United Arab Emirates - 2017.01.11 17:15

    Leave Your Messages

    Related products

    • Manufacturer for Chromogenic endotoxin detection - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      Manufacturer for Chromogenic endotoxin detectio...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...

    • China Cheap price LAL gel clot method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo

      China Cheap price LAL gel clot method - Gel Cl...

      Gel Clot Method Lyophilized Amebocyte Lysate Multi-test Vial G52 series 1. Product Information Gel Clot method Lyophilized Amebocyte Lysate Multi-test Vial is the Lyophilized Amebocyte Lysate reagent which select and use gel clot technique to detect endotoxin or pyrogen. As the widespread method, gel-clot test for endotoxin is simple and does not require specific and expensive instrument. Bioendo provides Gel Clot Lyophilized Amebocyte Lysate reagent in 5.2ml per vial. 2. Product Parameter...

    • OEM Manufacturer BET Test Procedure - Nymph X Water Purification System – Bioendo

      OEM Manufacturer BET Test Procedure - Nymph X ...

      NYMPHX Nymph X Water Purification System   Nymph X Water Purification System could transfer tap water into pure water and ultrapure water. Equipped with a pressure stabilizer and low flow-rate operating mode, the system can adapt to various source conditions without any extra pre-treatment necessary. The system also supports multiple water dispensing modes, and the precision of quantitative and quality-controlled dispense of water could reach ±1%. Meanwhile, comprehensive monitoring could be...

    • Low price for Bacterial Endotoxin Test Kinetic Turbidimetric Method – Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      Low price for Bacterial Endotoxin Test Kinetic ...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • China Cheap price TAL test - Rapid Gel Clot single test kit – Bioendo

      China Cheap price TAL test - Rapid Gel Clot si...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • High definition LAL Turbidimetric detection - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      High definition LAL Turbidimetric detection - ...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...