2022 High quality LAL gel clot test - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo


Product Detail

Related Video

Feedback (2)

Our primary purpose is to give our shoppers a serious and responsible company relationship, giving personalized attention to all of them for Bacterial Endotoxin Test Gel Clot Method, LAL endotoxin test kit, Endotoksin Testi, Created solutions with brand price. We attend seriously to produce and behave with integrity, and because of the favor of clients in your own home and overseas in the xxx industry.
2022 High quality LAL gel clot test - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo Detail:

Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial

1. Product Information

Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in Vial, you could add sample to the vial directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many vials use each time to avoid waste. Endotoxin free tube for dilution of CSE is necessary. Operation of endotoxin detection by choice of Bioendo Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial conforms to the USP, the EP.

2. Product Parameter

Gel clot assay single test glass vial

Sensitivities:  0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25 EU/ml

3.Product Feature and Application

Single step endotoxin detection,

without expensive endotoxin assay instruments,

Suitable for end-product endotoxin testing before product released,

Product sensitivity standardized according to US Pharmacopoeia criterion and China Pharmacopoeia criterion.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from lysate of amebocytes (white blood cells) from the horseshoe crab.

Catalog number Sensitivity (EU/ml) (IU/ml) Tests/Vial Vials/Pack
G020015 0.015 1 50
G020030 0.03 1 50
G020060 0.06 1 50
G020125 0.125 1 50
G020250 0.25 1 50
G020500 0.5 1 50

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

Why the most selected gel clot assay kit G02:

1. The most economical and commonly used test reagent for endotoxin detection.

2. Single test in a vial for one stepping reduce the risk of contamination.

3. Gel clot assay single test glass vial no need sophisticated microplate reader.

4. Saving endotoxin free tube when using G02 series to test endotoxins in the procedure of endotoxin test assay’s operation.

Related products in the endotoxin test assay:
Water for Bacterial Endotoxins Test (BET),  Recommend TRW50 or TRW100
Endotoxin free glass tube ( dilution tube ),  Recommend T1310018
Pyrogen free tips,  Recommend PT25096 or PT100096
Pipettor, Recommend PSB0220
Test Tube Rack,
Incubation Instrument (Water Bath or Dry Heat Incubator ), Recommend Dry Heat Incubator TAL-M2
Vortex Mixter, Recommend VXH.
Control Standard Endotoxin, CSE10V.

Product detail pictures:

2022 High quality LAL gel clot test - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures

2022 High quality LAL gel clot test - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures

2022 High quality LAL gel clot test - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures

2022 High quality LAL gel clot test - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures

2022 High quality LAL gel clot test - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures

2022 High quality LAL gel clot test - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo detail pictures


Related Product Guide:

We retain improving upon and perfecting our items and repair. At the same time, we perform actively to do research and progress for 2022 High quality LAL gel clot test - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo , The product will supply to all over the world, such as: Cyprus, Leicester, Singapore, we're now looking forward to even greater cooperation with overseas customers based on mutual benefits. We are going to work wholeheartedly to improve our products and services. We also promise to work jointly with business partners to elevate our cooperation to a higher level and share success together. Warmly welcome you to visit our factory sincerely.
  • On this website, product categories is clear and rich, I can find the product I want very quickly and easily, this is really very good!
    5 Stars By Arthur from Curacao - 2017.09.28 18:29
    Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.
    5 Stars By Esther from Hamburg - 2017.02.28 14:19

    Leave Your Messages

    Related products

    • Discount wholesale BET Endotoxin - Control Standard Endotoxin (CSE) – Bioendo

      Discount wholesale BET Endotoxin - Control Sta...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • Factory Cheap Hot Bacterial Endotoxin Test Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G17 – Bioendo

      Factory Cheap Hot Bacterial Endotoxin Test Gel ...

      Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial, G17 series 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial is the Lyophilized Amebocyte Lysate reagent which choose gel clot technique to detect endotoxin or pyrogen. As the widespread method, gel-clot test for endotoxin is simple and does not require specific and expensive instrument. Bioendo provides Gel Clot Lyophilized Amebocyte Lysate reagent in 1.7ml per vial. 2. Product Parameter Sensitivity range: 0....

    • High Quality Kinetic Chromogenic Endotoxin test kit - Endpoint Chromogenic Kit EC64405 – Bioendo

      High Quality Kinetic Chromogenic Endotoxin test...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • 100% Original 200ul Pipette tip - Compact Modular Dry Heat Incubator – Bioendo

      100% Original 200ul Pipette tip - Compact Modu...

      Dry Heat Incubator 1. Product description: Dry Heat Incubator TAL-M2 is amicroprocessor-controlled device, high precision of temperature control, samplepreparation parallelism, as an alternative to the traditional water bathdevice. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules. TAL- M2 A Dry bath incubat...

    • Wholesale Price BET Water - Vortex Mixer – Bioendo

      Wholesale Price BET Water - Vortex Mixer ̵...

      Vortex mixer 1. Product information The Vortex mixer widely used in life science, physical and chemicalanalysis fields, for vigorous re-suspension of cells or chemical pelletsin tubes up to 15 ml. It is good for the dilution and mixing the Control Standard Endotoxin solution in endotoxin assay with gel clot method, kinetic chromogenic method, kinetic turbidimetric method and end-point chromogenic method. 2. Features - Touch and continuous operations - with wide speed range of 0-2500rpm,st...

    • New Arrival China Dry heat tunnel validation by ECV - Single-Channel Mechanical Pipettor – Bioendo

      New Arrival China Dry heat tunnel validation by...

      Single-Channel Mechanical Pipettor   1. Product Information Single channel mechanical pipette is ideal tool to support endotoxin detection with Lyophilized Amebocyte Lysate which covers gel-clot technique, kinetic turbidimetric technique, kinetic chromogenic technique, and end-point chromogenic technique. All pipettors are produced by following ISO8655 – 2:2002. The quality control involves gravimetric testing of each pipette with distilled water at 22℃.   2. Product Features: - ...