Fast and superior quotations, informed advisers to help you choose the correct merchandise that suits all your requirements, a short generation time, responsible quality control and different services for paying and shipping affairs for endotoxin detection, Endotoxin free reagent reservoir, Kinetic Turbidimetric Endotoxin test Kit, We value your inquiry, For more details, please contact us, we will reply you ASAP!
2022 China New Design LAL test for endotoxin - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo Detail:

 Endotoxin Challenge Vials (Endotoxin Indicator)

 

1. Product Information

The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3-log reduction in endotoxin content when tested using gel clot endotoxin assay kit, kinetic turbidimetric endotoxin assay kit or chromogenic Lyophilized Amebocyte Lysate assay kits. Endotoxin Challenge Vial contains 1000 to 10000EU Endotoxins level in a glass vial. ECV1250V and ECV2500V are sealed in vials that configurate the heat resistant stoppers and heat resistant labels, which could be placed in dry-heat oven or dry-heat tunnel without removal of stoppers and caps(lid).

Validation of dry heat sterilization cycle(s) is required by regulations of ANSI, AAMI, ISO, USP and FDA to ensure that all items that are required to be sterile or endotoxin-free are able to consistently and reliably be sterilized to reduce the chance of introducing or spreading an infectious micro-organism or pyrogens.

Follow the Regulations requirement, use Bioendo ECV is able to operate the endotoxin free validation or pyrogen free validation. More important information is Bioendo ECV no need rubber lid(cap) removal in the heating operation.

 

2. Product Parameter

The potency: 1000 to 10000 EU per vial and 2000 to 10000 EU in a vial.  

 

3. Product Features and Application

In vial with heat resistant stopper (tolerable high temperature up to 360 Celsius degree) and heat resistant label. 

In the procedure of baking or drying, ECV vial’s lid no need to remove. 

Without excipient.  

Endotoxin Challenge Vial  (10ml glass bottle and 2ml of ISO standard 2R glass bottle)

Catalog No.

Endotoxins Level (EU/vial)

Package

ECV1250V

1000-10000

In Vial, 10 Vials/Pack

ECV1250VR

 1000-10000

ISO 2R vial, 10 Vials/Pack

ECV2500V

2000-10000

In Vial, 10 Vials/Pack

ECV2500VR

 2000-10000

ISO 2R vial, 10 Vials/Pack

ECV100000V

50000-200000

In Vial, 10 Vials/Pack

How is the features of Bioendo’s Endotoxin Challenge Vails (Endotoxin Indicator)?

Endotoxin challenge vial, in the operation procedures, the lysate reagent has to match the ECV kit, and no need remove the lit during the baking procedure.


Product detail pictures:

2022 China New Design LAL test for endotoxin - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo detail pictures

2022 China New Design LAL test for endotoxin - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo detail pictures

2022 China New Design LAL test for endotoxin - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo detail pictures

2022 China New Design LAL test for endotoxin - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo detail pictures


Related Product Guide:

We've got a really efficient group to deal with inquiries from prospects. Our purpose is "100% customer fulfillment by our product excellent, price & our group service" and enjoy a superb track record amid clientele. With many factories, we can easily deliver a wide selection of 2022 China New Design LAL test for endotoxin - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo , The product will supply to all over the world, such as: Cyprus, Naples, Washington, We have a strict and complete quality control system, which ensures that each product can meet quality requirements of customers. Besides, all of our products have been strictly inspected before shipment.
  • This company has the idea of "better quality, lower processing costs, prices are more reasonable", so they have competitive product quality and price, that's the main reason we chose to cooperate.
    5 Stars By Lorraine from Jersey - 2018.06.21 17:11
    This company has a lot of ready-made options to choose and also could custom new program according to our demand, which is very nice to meet our needs.
    5 Stars By Betty from Palestine - 2018.12.25 12:43

    Leave Your Messages

    Related products

    • 100% Original Endotoxin free glass tube - Control Standard Endotoxin (CSE) – Bioendo

      100% Original Endotoxin free glass tube - Cont...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • Manufacturer of Dry Heat Sterilization Validation – Mini Dry Heat Incubator – Bioendo

      Manufacturer of Dry Heat Sterilization Validati...

      Dry heat incubator single module 1. Product information  The Mini Dry Heat Incubator is a micro-processor controlled heating block with semi conductor heating technology.It adapts onboard use, smart, light and convenient for movement, suit for any kind of occasions. Especially good for the incubation of the gel clot LAL assay, LAL chromogenic endpoint assay incubation. 2. Product features 1. Unique designed. Smart and light, convenient movement, suit for various occasions. 2. LCD simultaneou...

    • OEM/ODM China Dry heat sterilizer validation by ECV - Rapid Gel Clot 10 Samples Kit – Bioendo

      OEM/ODM China Dry heat sterilizer validation by...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Wholesale Price Endotoxin challenge vial - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      Wholesale Price Endotoxin challenge vial - Pyr...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • Wholesale Dealers of Bacterial Endotoxin Test Sop - Endotoxin-free Glass Test Tubes – Bioendo

      Wholesale Dealers of Bacterial Endotoxin Test S...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • 2022 Good Quality Kinetic chromogenic TAL test - Endpoint Chromogenic Kit EC64405 – Bioendo

      2022 Good Quality Kinetic chromogenic TAL test ...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...