As for competitive selling prices, we believe that you will be searching far and wide for anything that can beat us. We will state with absolute certainty that for such excellent at such charges we are the lowest around for Pyrogen free microplate, Bacteria Producing Endotoxin, LAL Turbidimetric assay, Customer satisfaction is our main goal. We welcome you to establish business relation with us. For further information, please don't hesitate to contact with us.
2022 China New Design LAL chromogenic test - Endpoint Chromogenic Kit EC80545 – Bioendo Detail:

Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling)

1. Product Information

Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum absorbance at 545nm. A regular spectrophotometer or microplate reader is required for the assay. The purple items are proportional to endotoxin concentration. Then endotoxin testing result is quantitative analysis. 

2. Product Parameter

Sensitivity Range: 0.01-0.1EU/ml (assay time about 46 minutes)

                             0.1-1.0EU/ml (assay time about 16 minutes)

3. Product Features and Application

Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) is intended for use in the In Vitro detection and quantitation of gram-negative bacterial endotoxins. The colorless artificial peptide substrate solution is added into Lyophilized Amebocyte Lysate, and then test specimen mixture. If specimen contains endotoxin, color of specimen mixture changes. The absorbance is related to the endotoxin concentration. Therefore the endotoxn levels in specimen mixture can be claculated against a standard curve. Standard spectrophotometer with 540 – 545nm filter is enough to quantify endotoxin with our EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling).

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

EC80545

Bioendo™ EC Endotoxin Test Kit

(End-point Chromogenic Assay,

Diazo Coupling),

80 Tests/Kit

5 Lyophilized Amebocyte Lysate, 1.7ml/vial;

4 Water for BET, 50ml/vial;

5 CSE;

5 Chromogenic Substrate, 1.7ml/vial;

5 Diazo Reagent 1, 10ml/vial;

5 Diazo Reagent 2, 10ml /vial;

5 Diazo Reagent 3, 10ml/vial;

0.1 – 1 EU/ml

EC80545S

0.01 – 0.1 EU/ml;

0.1 – 1 EU/ml

Product Conditions

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

 

Does the End point endotoxin test kit need sophisticated microplate reader?

Bioendo EC80545 and EC80545S, can read by regular spectrophotometer. 

Bioendo End point chromogenic endotoxin test kit series:
Endotoxin Free Tube
Pyrogen Free Tips
Pyrogen Free Microplates
normal Microplate reader
Water Bath or Dry Heat Incubator 

Product detail pictures:


Related Product Guide:

We believe that long expression partnership is often a result of top of the range, value added service, prosperous encounter and personal contact for 2022 China New Design LAL chromogenic test - Endpoint Chromogenic Kit EC80545 – Bioendo , The product will supply to all over the world, such as: Hungary, South Africa, Colombia, Customer satisfaction is our first goal. Our mission is to pursue the superlative quality, making continual progress. We sincerely welcome you to make progress hand in hand with us, and construct a prosperous future together.
Superb technology, perfect after-sales service and efficient work efficiency, we think this is our best choice.
5 Stars By Deirdre from Peru - 2018.11.11 19:52
The company's products very well, we have purchased and cooperated many times, fair price and assured quality, in short, this is a trustworthy company!
5 Stars By Rebecca from Belgium - 2018.06.21 17:11

Leave Your Messages

Related products

  • Wholesale Pyrogen free tip - Rapid Gel Clot single test kit – Bioendo

    Wholesale Pyrogen free tip - Rapid Gel Clot si...

    Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

  • Professional Design Bacterial Endotoxin Test Usp Limit - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

    Professional Design Bacterial Endotoxin Test Us...

    Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

  • Hot sale Kinetic Turbidimetric TAL Assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

    Hot sale Kinetic Turbidimetric TAL Assay - Bio...

    Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

  • New Arrival China Kinetic Turbidimetric Method endotoxin - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

    New Arrival China Kinetic Turbidimetric Method ...

    Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...

  • OEM/ODM China Kinetic chromogenic TAL test kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

    OEM/ODM China Kinetic chromogenic TAL test kit ...

    Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...

  • Chinese Professional Chromogenic assays - Endpoint Chromogenic Kit EC64405 – Bioendo

    Chinese Professional Chromogenic assays - Endp...

    End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...