2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo


Product Detail

Related Video

Feedback (2)

We also present product or service sourcing and flight consolidation products and services. We have our possess manufacturing facility and sourcing place of work. We can easily supply you with almost every type of product or service connected to our item variety for BET Test In Pharma, Endotoxin Assay Kits, BET Test Procedure, We sincerely welcome clients from both of those at your home and overseas to occur to barter business enterprise with us.
2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo Detail:

Gel Clot Method Lyophilized Amebocyte Lysate Multi-test Vial G52 series

1. Product Information

Gel Clot method Lyophilized Amebocyte Lysate Multi-test Vial is the Lyophilized Amebocyte Lysate reagent which select and use gel clot technique to detect endotoxin or pyrogen.

As the widespread method, gel-clot test for endotoxin is simple and does not require specific and expensive instrument. Bioendo provides Gel Clot Lyophilized Amebocyte Lysate reagent in 5.2ml per vial.

2. Product Parameters

Sensitivity range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5 EU/ml 

3. Product Application

End-product endotoxin (pyrogen) qualification, waterfor injection endotoxin assay, raw material endotoxin testing or endotoxinlevel monitoring during manufacturing process for pharmaceutical companies ormedical devices manufacturers.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from lysate of amebocytes (white blood cells) from the horseshoe crab.

Gel clot method LAL assay, reconstituted lysate reagent get at least 50 tests per vial:
Catalog Number Sensitivity (EU/ml or IU/ml) ml/vial Tests/Vial Vials/Pack
G520030 0.03 5.2 50 10
G520060 0.06 5.2 50 10
G520125 0.125 5.2 50 10
G520250 0.25 5.2 50 10
G520500 0.5 5.2 50 10

Product condition

The Lyophilized Amebocyte Lysate reagent sensitivity and the Control Standard Endotoxin potency are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte reagent kits come with product instruction, Certificate of Analysis, MSDS.

 

What is the difference between single test and multiple test?

● Single test: reconstitute the single test lysate reagent by BET water in the glass vial or glass ampoule.

● Multi-test: reconstitute the lysate reagent with BET water, and then add marked amount of lysate reagent following COA to the reaction tube or well plate for use. There is no difference in the sample pre-processing procedure; according to the amount of testing used, the sample size used for a single test is larger than the sample size used for multiple tests.

 

Why the most selected gel clot assay kit G52:

1. Multi test reagent for endotoxin detection in the applications of certain samples’ endotoxin detection.

2. G52 series of Gel clot assay multi test glass vial no need sophisticated microplate reader. Procedure of incubation by water bath or dry heat incubator.

3. High end quality of endotoxin free tube (<0.005EU/ml) and High quality of pyrogen free tips (<0.005EU/ml) as the guaranteed consumables to ensure the correct result.

Related products in the endotoxin test assay:
Water for Bacterial Endotoxins Test (BET),  Recommend TRW50 or TRW100
Endotoxin free glass tube ( dilution tube ),  Recommend T1310018 and T107540
Pyrogen free tips,  Recommend PT25096 or PT100096
Pipettor, Recommend PSB0220
Test Tube Rack,
Incubation Instrument (Water Bath or Dry Heat Incubator ), Recommend Dry Heat Incubator TAL-M2
Vortex Mixter, Recommend VXH.
Control Standard Endotoxin, CSE10V.

Product detail pictures:

2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures

2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures

2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures

2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures

2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures


Related Product Guide:

We'll make every effort and hard work to be superb and excellent, and speed up our steps for standing inside the rank of intercontinental top-grade and high-tech enterprises for 2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo , The product will supply to all over the world, such as: Albania, Sudan, Cyprus, Hard work to keep making progress, innovation in the industry, make every effort to first-class enterprise. We try our best to build the scientific management model, to learn abundant experienced knowledge, to develop advanced production equipment and production process , to create the first-call quality goods, reasonable price , high quality of service , quick delivery , to present you create new value .
  • Superb technology, perfect after-sales service and efficient work efficiency, we think this is our best choice.
    5 Stars By Matthew Tobias from Malawi - 2017.07.28 15:46
    The company account manager has a wealth of industry knowledge and experience, he could provide appropriate program according our needs and speak English fluently.
    5 Stars By Maureen from Czech Republic - 2018.11.02 11:11

    Leave Your Messages

    Related products

    • Competitive Price for Endotoxin Is Produced By - Control Standard Endotoxin (CSE) – Bioendo

      Competitive Price for Endotoxin Is Produced By ...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • OEM/ODM Supplier Kit LAL - Single-Channel Mechanical Pipettor – Bioendo

      OEM/ODM Supplier Kit LAL - Single-Channel Mech...

      Single-Channel Mechanical Pipettor   1. Product Information Single channel mechanical pipette is ideal tool to support endotoxin detection with Lyophilized Amebocyte Lysate which covers gel-clot technique, kinetic turbidimetric technique, kinetic chromogenic technique, and end-point chromogenic technique. All pipettors are produced by following ISO8655 – 2:2002. The quality control involves gravimetric testing of each pipette with distilled water at 22℃.   2. Product Features: - ...

    • Hot sale Pyrogen free tip box - Nymph X Water Purification System – Bioendo

      Hot sale Pyrogen free tip box - Nymph X Water ...

      NYMPHX Nymph X Water Purification System   Nymph X Water Purification System could transfer tap water into pure water and ultrapure water. Equipped with a pressure stabilizer and low flow-rate operating mode, the system can adapt to various source conditions without any extra pre-treatment necessary. The system also supports multiple water dispensing modes, and the precision of quantitative and quality-controlled dispense of water could reach ±1%. Meanwhile, comprehensive monitoring could be...

    • Excellent quality Depyrogenated pipette tips - Mini Dry Heat Incubator – Bioendo

      Excellent quality Depyrogenated pipette tips -...

      Dry heat incubator single module 1. Product information  The Mini Dry Heat Incubator is a micro-processor controlled heating block with semi conductor heating technology.It adapts onboard use, smart, light and convenient for movement, suit for any kind of occasions. Especially good for the incubation of the gel clot LAL assay, LAL chromogenic endpoint assay incubation. 2. Product features 1. Unique designed. Smart and light, convenient movement, suit for various occasions. 2. LCD simultaneou...

    • OEM Supply BET Test Method - Mini Dry Heat Incubator – Bioendo

      OEM Supply BET Test Method - Mini Dry Heat Inc...

      Dry heat incubator single module 1. Product information  The Mini Dry Heat Incubator is a micro-processor controlled heating block with semi conductor heating technology.It adapts onboard use, smart, light and convenient for movement, suit for any kind of occasions. Especially good for the incubation of the gel clot LAL assay, LAL chromogenic endpoint assay incubation. 2. Product features 1. Unique designed. Smart and light, convenient movement, suit for various occasions. 2. LCD simultaneou...

    • Factory wholesale Kinetic Turbidimetric LAL Assay - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      Factory wholesale Kinetic Turbidimetric LAL Ass...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...