Assume full responsibility to satisfy all needs of our clients; achieve continual advancements by endorsing the expansion of our purchasers; turn into the final permanent cooperative partner of clientele and maximize the interests of clients for LAL chromogenic test, limulus lysate test, BET Endotoxin, Now now we have recognized steady and long organization relationships with customers from North America, Western Europe, Africa, South America, extra than 60 countries and regions.
2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G17 – Bioendo Detail:

Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial, G17 series

1. Product Information

Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial is the Lyophilized Amebocyte Lysate reagent which choose gel clot technique to detect endotoxin or pyrogen. As the widespread method, gel-clot test for endotoxin is simple and does not require specific and expensive instrument. Bioendo provides Gel Clot Lyophilized Amebocyte Lysate reagent in 1.7ml per vial.

2. Product Parameter

Sensitivity range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5 EU/ml 

3. Product Application

End-product endotoxin (pyrogen) qualification,

water for injection endotoxin assay,

raw material endotoxin testing or endotoxin level monitoring during manufacturing process for pharmaceutical companies or medical devices manufacturers.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from lysate of amebocytes (white blood cells) from the horseshoe crab.

Gel clot method LAL assay, reconstituted lysate reagent get at least 16 tests per vial:
Catalog Number Sensitivity (EU/ml or IU/ml) ml/vial Tests/Vial Vials/Pack
G170030 0.03 1.7 16 10
G170060 0.06 1.7 16 10
G170125 0.125 1.7 16 10
G170250 0.25 1.7 16 10
G170500 0.5 1.7 16 10

 

Product condition: 

The Lyophilized Amebocyte Lysate reagent sensitivity and the Control Standard Endotoxin potency are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte reagent kits come with product instruction, Certificate of Analysis.

 

Why the most selected gel clot assay kit G17:

1. Multi test reagent for endotoxin detection in the applications of certain samples’ endotoxin detection.

2. G17 series of Gel clot assay multi test glass vial no need sophisticated microplate reader.

3. Procedure of incubation by water bath or dry heat incubator.

4. High end quality of endotoxin free tube (<0.005EU/ml) and High quality of pyrogen free tip (<0.005EU/ml) as the guaranteed consumables to ensure the correct result.

 

Related products in the endotoxin test assay:
Water for Bacterial Endotoxins Test (BET),  Recommend TRW50 or TRW100
Endotoxin free glass tube ( dilution tube ),  Recommend T1310018 and T107540
Pyrogen free tips,  Recommend PT25096 or PT100096
Pipettor, Recommend PSB0220
Test Tube Rack,
Incubation Instrument (Water Bath or Dry Heat Incubator ), Recommend Dry Heat Incubator TAL-M2
Vortex Mixter, Recommend VXH.
Control Standard Endotoxin, CSE10V.

 


Product detail pictures:

2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G17 – Bioendo detail pictures

2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G17 – Bioendo detail pictures

2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G17 – Bioendo detail pictures

2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G17 – Bioendo detail pictures

2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G17 – Bioendo detail pictures


Related Product Guide:

Fast and great quotations, informed advisers to help you choose the correct product that suits all your preferences, a short creation time, responsible top quality control and different services for paying and shipping affairs for 2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G17 – Bioendo , The product will supply to all over the world, such as: Riyadh, Pakistan, Switzerland, All the imported machines effectively control and guarantee the machining precision for the products. Besides, we have a group of high-quality management personnels and professionals, who make the high-quality products and have the ability to develop new products to expand our market home and abroad. We sincerely expect customers come for a blooming business for both of us.
  • In general, we are satisfied with all aspects, cheap, high-quality, fast delivery and good procuct style, we will have follow-up cooperation!
    5 Stars By April from El Salvador - 2017.06.16 18:23
    Company director has very rich management experience and strict attitude, sales staff are warm and cheerful, technical staff are professional and responsible,so we have no worry about product,a nice manufacturer.
    5 Stars By Gail from Grenada - 2018.12.11 11:26

    Leave Your Messages

    Related products

    • OEM Manufacturer BET Test Procedure - Compact Modular Dry Heat Incubator – Bioendo

      OEM Manufacturer BET Test Procedure - Compact ...

      Dry Heat Incubator 1. Product description: Dry Heat Incubator TAL-M2 is amicroprocessor-controlled device, high precision of temperature control, samplepreparation parallelism, as an alternative to the traditional water bathdevice. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules. TAL- M2 A Dry bath incubat...

    • 2022 Good Quality LAL assay endotoxin - Control Standard Endotoxin (CSE) – Bioendo

      2022 Good Quality LAL assay endotoxin - Contro...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • New Arrival China Kinetic Turbidimetric Method endotoxin - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      New Arrival China Kinetic Turbidimetric Method ...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • Manufacturing Companies for Advantages Of LAL Test - Rapid Gel Clot 10 Samples Kit – Bioendo

      Manufacturing Companies for Advantages Of LAL T...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Factory Cheap Hot LAL test endotoxin - Endotoxin-free Glass Test Tubes – Bioendo

      Factory Cheap Hot LAL test endotoxin - Endotox...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • Best quality limulus lysate assay - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo

      Best quality limulus lysate assay - Endotoxin-...

      Endotoxin-specific Lyophilized Amebocyte Lysate 1. Product Information Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples ...